2019
DOI: 10.1002/cam4.2478
|View full text |Cite
|
Sign up to set email alerts
|

BRAFV600E mutation analysis in fine‐needle aspiration cytology specimens for diagnosis of thyroid nodules: The influence of false‐positive and false‐negative results

Abstract: Background The accurate evaluation of BRAFV600E mutation in preoperative fine‐needle aspiration cytology (FNAC) specimens is important for making management decisions in thyroid nodules (TNs). The aim of this study was to assess the false‐positive and false‐negative BRAFV600E mutations in thyroid FNAC specimens and their influence on diagnosis of TN. Methods This prospective study enrolled 292 nodules in 269 patients who underwent BRAFV600E mutation analysis using amplification refractory mutation system‐quant… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
16
1

Year Published

2019
2019
2023
2023

Publication Types

Select...
9
1

Relationship

1
9

Authors

Journals

citations
Cited by 27 publications
(17 citation statements)
references
References 28 publications
0
16
1
Order By: Relevance
“…Unfortunately, it is not clear if the poor performance of the assay is due to the FNA samples since the mutational analysis has not been confirmed on the matched FFPE slides. Despite other papers reported a better specificity of the same assay on thyroid FNAs, this study raises doubts on the reliability of this methodology, suggesting the need for further investigations before clinical applicability. To date, other robust technologies, such as next‐generation sequencing, have been extensively tested with a very high analytical sensitivity and specificity for BRAF mutation detection in patients with different ethnic background.…”
contrasting
confidence: 72%
“…Unfortunately, it is not clear if the poor performance of the assay is due to the FNA samples since the mutational analysis has not been confirmed on the matched FFPE slides. Despite other papers reported a better specificity of the same assay on thyroid FNAs, this study raises doubts on the reliability of this methodology, suggesting the need for further investigations before clinical applicability. To date, other robust technologies, such as next‐generation sequencing, have been extensively tested with a very high analytical sensitivity and specificity for BRAF mutation detection in patients with different ethnic background.…”
contrasting
confidence: 72%
“…We found only one false-positive mutation case, confirmed as adenomatous hyperplasia with underlying lymphocytic thyroiditis by surgical pathology. Surgically proven benign cases of falsepositive BRAF V600E mutation have been documented in the literature [55][56][57]. False-positive results can be mainly explained by the trade-off of improved sensitivity by sacrificing specificity.…”
Section: Discussionmentioning
confidence: 99%
“…one nodule had an unde ned boundary, and the other nodule extended from the isthmus but had a clear boundary. There were two reasons for this situation in the analysis, one was that the FNA BRAF V600E test was false positive before surgery; the other was that the nodule gene was mutated, but the cellular tissue morphology had not changed signi cantly and cannot be diagnosed malignant by histology [29].…”
Section: Discussionmentioning