2018
DOI: 10.1364/boe.9.000873
|View full text |Cite
|
Sign up to set email alerts
|

Bounded Kalman filter method for motion-robust, non-contact heart rate estimation

Abstract: The authors of this work present a real-time measurement of heart rate across different lighting conditions and motion categories. This is an advancement over existing remote Photo Plethysmography (rPPG) methods that require a static, controlled environment for heart rate detection, making them impractical for real-world scenarios wherein a patient may be in motion, or remotely connected to a healthcare provider through telehealth technologies. The algorithm aims to minimize motion artifacts such as blurring a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
17
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
5
3

Relationship

1
7

Authors

Journals

citations
Cited by 49 publications
(17 citation statements)
references
References 58 publications
0
17
0
Order By: Relevance
“…The current research methods focus on illumination [ 16 , 20 ], motion [ 20 , 21 , 22 ], video compression [ 19 ], and other aspects, but less attention is paid to the selection of regions of interest, the impact of face detection methods, and the datasets suitable for heart rate detection.…”
Section: Related Workmentioning
confidence: 99%
See 2 more Smart Citations
“…The current research methods focus on illumination [ 16 , 20 ], motion [ 20 , 21 , 22 ], video compression [ 19 ], and other aspects, but less attention is paid to the selection of regions of interest, the impact of face detection methods, and the datasets suitable for heart rate detection.…”
Section: Related Workmentioning
confidence: 99%
“…At present, rPPG is tentatively applied in Intensive Care Units (ICU), because the subjects are still and a frontal face video can be continuously collected. Under these ideal conditions, the root mean square error (RMSE) of the traditional non-contact heart rate measurement method is between 1.24 and 8.90 bpm [ 16 , 27 , 39 , 40 ]. The frontal face RMSE of our proposed method reaches 3.49 bpm, which is very close to state-of-the-art traditional methods.…”
Section: Related Workmentioning
confidence: 99%
See 1 more Smart Citation
“…Furthermore, the multi view human pose estimation process is described in [20][21][22]. For determining heart rate, 2 Motion Capture Systems Using Optimal Signal Processing Algorithm: A State-of-the-art Literature a KF algorithm is used in [23,24]. It has a significant role not only in the medical science but also in weather forecasting [25].…”
Section: Literature Reviewmentioning
confidence: 99%
“…Partial demographic analysis (across skin tones) was performed in this study. The VideoVitals approach developed by Prakash and Tucker employs a bounded Kalman Filter (BKF) and a denoising algorithm to reduce the effect of motion and improve feature tracking 34 . The BKF algorithm is tested on subjects performing a range of head motions and is shown to outperform the existing methods for reducing motion inaccuracies.…”
Section: Introductionmentioning
confidence: 99%