2003
DOI: 10.1111/j.1708-8208.2003.tb00191.x
|View full text |Cite
|
Sign up to set email alerts
|

Bone Healing around Titanium and Titanium Nitride‐Coated Dental Implants with Three Surfaces: An Experimental Study in Rats

Abstract: TiN coating demonstrated a good biocompatibility, did not have untoward effects on the periimplant bone formation, and did not change the surface roughness values.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
18
0

Year Published

2005
2005
2018
2018

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 28 publications
(19 citation statements)
references
References 30 publications
1
18
0
Order By: Relevance
“…The main finding of the presented investigation is the feasibility of the SEM‐EDS technique to preserve biological probes despite the exposure towards radiation. The presented results relative to the effect of insertion of implants with different surface structures correlated with previous published studies, where it was observed that insertion of rough implants led to a greater extent of titanium wear than smooth surfaces (Goodman et al 1996; Budd et al 1999; Scarano et al 2003). In contrast to these studies, Wennerberg et al (2004) were unable to verify a difference in ionic leakage after insertion of implants with different roughnesses in the tibiae of rabbits.…”
Section: Discussionsupporting
confidence: 87%
See 1 more Smart Citation
“…The main finding of the presented investigation is the feasibility of the SEM‐EDS technique to preserve biological probes despite the exposure towards radiation. The presented results relative to the effect of insertion of implants with different surface structures correlated with previous published studies, where it was observed that insertion of rough implants led to a greater extent of titanium wear than smooth surfaces (Goodman et al 1996; Budd et al 1999; Scarano et al 2003). In contrast to these studies, Wennerberg et al (2004) were unable to verify a difference in ionic leakage after insertion of implants with different roughnesses in the tibiae of rabbits.…”
Section: Discussionsupporting
confidence: 87%
“…Whereas Woodman et al (1984) failed to find any pathology associated with titanium leakage in a long‐term animal study, particulate debris has been shown by others to promote fibroblast proliferation, being an important factor in the creation of the fibrous membrane surrounding the implant surface (Garcia‐Alonso et al 2003). Moreover, the phagocytosis of the particles by different cells has been demonstrated to be indirectly responsible for peri‐implant osteolysis (Bi et al 2001; Scarano et al 2003). As ‘aseptic’ implant failure does occur and as the underlying reasons for some implant failures are multi‐causal, the influence of single parameters are not entirely known.…”
Section: Discussionmentioning
confidence: 99%
“…Weiss et al14 conducted experiments using 7 implant systems and opening torque was measured after 30 times and 200 times of repeated tightening and loosening of upper part, and reported that as the repetition increases, opening torque decreases. Also, they proposed that the decrease of the frictional coefficient caused by abrasion between abutment screw and its component due to repeated tightening and loosening of upper part, was the cause of decreased open torque.…”
Section: Discussionmentioning
confidence: 99%
“…However, with the recent development of TiN coating technique, some dentists began to apply the TiN coating to the implant system. Scarano et al14,15 reported that TiN coating had good biocompatibility and it didn't have negative influence to the bone around the implant fixture, and it did not change the surface roughness as well. Researches about the application of TiN coating to the abutment screw are not enough.…”
Section: Introductionmentioning
confidence: 99%
“…In addition, the dental implant is also required to have hard tissue compatibility because it is seated tightly in the alveolar bone. For hard tissue compatibility, surface-modified dental implants using hydroxyapatite coating or titanium nitride coating are already available on the market 1,2) . Apart from surface modification by coatings, increasing the roughness of dental implant surface by sandblasting or by machined grooves are also alternative techniques that are widely known to improve hard tissue compatibility 3,4) .…”
Section: Introductionmentioning
confidence: 99%