Comprehensive Electrocardiology 2010
DOI: 10.1007/978-1-84882-046-3_32
|View full text |Cite
|
Sign up to set email alerts
|

Body Surface Potential Mapping

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
13
0
2

Year Published

2014
2014
2021
2021

Publication Types

Select...
3
1
1

Relationship

0
5

Authors

Journals

citations
Cited by 8 publications
(16 citation statements)
references
References 124 publications
1
13
0
2
Order By: Relevance
“…[144,504,505,511]. The spreading of these techniques of potential recording is motivated by the fact that BSM provide diagnostic information which could not be obtained by conventional electrocardiograms in many heart diseases, such as Wolff-Parkinson-White and myocardial ischemia.…”
Section: The Inverse Problem Of Electrocardiologymentioning
confidence: 99%
“…[144,504,505,511]. The spreading of these techniques of potential recording is motivated by the fact that BSM provide diagnostic information which could not be obtained by conventional electrocardiograms in many heart diseases, such as Wolff-Parkinson-White and myocardial ischemia.…”
Section: The Inverse Problem Of Electrocardiologymentioning
confidence: 99%
“…Using BSPM during the period of ventricular repolarization in healthy adults, variants of the distribution of zones and extrema of cardiopotentials on the torso surface were described (Roshchevskaya, 2008;De Ambroggi and Corlan, 2011). Therefore, in the initial state and under HH and HCH, the location of the zones and extrema of cardiopotential in swimmers and untrained people corresponded to those in healthy subjects.…”
Section: Discussionmentioning
confidence: 99%
“…However, such ECG changes are not highly specific and can appear with other functional and morphological changes in the myocardium (Macfarlane and Lawrie, 2011). Registration and analysis of unipolar electrocardiograms from multiple leads on the surface of the chest (body surface potential mapping [BSPM] method) have high sensitivity and help to obtain detailed information about electrophysiological processes (Mirvis 1988;De Ambroggi and Corlan, 2011;Polyakova et al, 2015;Strutynsky et al, 2015;Wissner et al, 2017). The information obtained using this method includes the amplitude, temporal, and spatial components of the signal, and it is used to localize and evaluate the area of ischemic damage of the heart muscle, myocardial electrical inhomogeneity and its hypertrophic remodeling (Magomedova et al, 2016;Tsyganov et al, 2018) and to diagnose cardiac arrhythmias, cardiomyopathies, and myocardial hypertrophy (Bond et al, 2013;Treshkur et al, 2014;Srinivasan et al, 2019).…”
Section: Introductionmentioning
confidence: 99%
“…These test shocks provide a rare opportunity to record the ICD potential maps in patients. Although BSPM is a well established technique, 24,25,26,27,28 using it during defibrillation and in the catheterization laboratory environment requires additional consideration to allow space on the torso surface for the sterile implantation region, the external defibrillation pads, and other instruments for the safety of the patient. Consequently, there is a highly limited and variable area of the torso surface that is available for the placement of validation BSPM lead systems.…”
Section: Introductionmentioning
confidence: 99%