2022
DOI: 10.3345/cep.2021.00143
|View full text |Cite
|
Sign up to set email alerts
|

Blood pressure measurements and hypertension in infants, children, and adolescents: from the postmercury to mobile devices

Abstract: A mercury sphygmomanometer (MS) has been the gold standard for pediatric blood pressure (BP) measurements, and diagnosing hypertension is critical. However, because of environmental issues, other alternatives are needed. Non-invasive BP measurement devices are largely divided into auscultatory and oscillometric types. The aneroid sphygmomanometer, the currently used auscultatory method, is inferior to mercury sphygmomanometers in terms of limitations such as validation and regular calibration and difficult to … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 39 publications
(65 reference statements)
0
4
0
1
Order By: Relevance
“…The device has been validated in adults against the well-established SphygmoCor applanation tonometry device, combining the measurement of brachial BP, pulse wave analysis and central BP in one measurement [ 31 , 32 , 33 ]. Although the oscillometric noninvasive methods of acquiring this data are not completely validated in children, there are multiple studies that affirm that these devices’ accuracy is comparable to mercury sphygmomanometry [ 34 , 35 , 36 ]. The main issue seems to be the accuracy of the systolic peripheral BP and the central systolic BP, which, according to Mynard et al, could be overestimated [ 37 ].…”
Section: Discussionmentioning
confidence: 99%
“…The device has been validated in adults against the well-established SphygmoCor applanation tonometry device, combining the measurement of brachial BP, pulse wave analysis and central BP in one measurement [ 31 , 32 , 33 ]. Although the oscillometric noninvasive methods of acquiring this data are not completely validated in children, there are multiple studies that affirm that these devices’ accuracy is comparable to mercury sphygmomanometry [ 34 , 35 , 36 ]. The main issue seems to be the accuracy of the systolic peripheral BP and the central systolic BP, which, according to Mynard et al, could be overestimated [ 37 ].…”
Section: Discussionmentioning
confidence: 99%
“…The IEM Mobil-O-Graph device was chosen because, in addition to being a validated device [47], its use is facile, reproducible, and has very good acceptability in children. Multiple studies confirm that the oscillometric devices acquire accurate measurements even in children [47][48][49].…”
Section: The Evaluation Of Arterial Stiffness Using the Mobil-o-graphmentioning
confidence: 87%
“…The precision of the aneroid sphygmomanometer depends on the operator’s proficiency in auscultation, use of a stethoscope, and visual acuity [ 42 ]. More recently, hybrid sphygmomanometers have been used to automate the detection of Korotkoff sounds and the display of the SBP, DSP, and pulse rate on digital monitors [ 44 ]. Notably, aneroid sphygmomanometers have varying accuracy across manufacturers.…”
Section: Blood Pressure Measurement Methodsmentioning
confidence: 99%