2002
DOI: 10.2116/bunsekikagaku.51.111
|View full text |Cite
|
Sign up to set email alerts
|

Blood glucose determination with the reduction of resazurin as a fluorometric indicator reaction.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
8
0

Year Published

2004
2004
2019
2019

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(10 citation statements)
references
References 10 publications
1
8
0
Order By: Relevance
“…Optimal concentration of resazurin dye was determined to be 0.1 mM since at higher concentrations it behaves as an inhibitor of CDH activity (Figure 2). Drop in fluorescence signal produced by enzymatic action at higher concentrations of resazurin (above 0.025 mM) was also previously reported for diaphorase coupled detection of glucose [35]. Drop in the enzyme activity at higher resazurin concentrations were results of substrate inhibition phenomenon that is often caused by nonproductive binding of the substrate for the enzyme active site.…”
Section: Discussionsupporting
confidence: 67%
See 1 more Smart Citation
“…Optimal concentration of resazurin dye was determined to be 0.1 mM since at higher concentrations it behaves as an inhibitor of CDH activity (Figure 2). Drop in fluorescence signal produced by enzymatic action at higher concentrations of resazurin (above 0.025 mM) was also previously reported for diaphorase coupled detection of glucose [35]. Drop in the enzyme activity at higher resazurin concentrations were results of substrate inhibition phenomenon that is often caused by nonproductive binding of the substrate for the enzyme active site.…”
Section: Discussionsupporting
confidence: 67%
“…Therefore, we tested fluorogenic resazurin dye as a substrate for detection of CDH activity on the surface of yeast cells. Resazurin reduction to resorufin that can be measured by red fluorescence was used previously for measuring viability of living cells [24] and blood glucose concentration [35]. The CDH assay using resazurin was optimized with respect to resazurin, cellobiose/lactose concentration, and pH of the reaction medium.…”
Section: Discussionmentioning
confidence: 99%
“…To date, spectrofluorometric methods using various enzymes have been developed for the determination of uric acid 6) and glucose. [7][8][9][10] However, no report has been published on the spectrofluorometric method using a peroxidase mimic such as Fe 3+ -TCAS [4] A-500 .…”
Section: )mentioning
confidence: 99%
“…Although redox indicators that directly or via a mediator accept an electron from an oxidizing enzyme instead of oxygen are preferred, they also have some problems. For example, resazurin, transition metal Os and Ru complexes are oxygen-independent fluorescent indicators for glucose (Matsu-Ura et al, 2002;Ryabov et al, 1999;Woltman et al, 1999). In the case of transition metals, their fluorescence efficiency varies with the oxygen content of the sample.…”
Section: Introductionmentioning
confidence: 99%