Blood gas values in clamped and unclamped umbilical cord at birth

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
16
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 20 publications
(18 citation statements)
references
References 21 publications
2
16
0
Order By: Relevance
“…It is a low resistance vascular bed, which promotes the fetalto-maternal exchange of deoxygenated blood under low pressure [3,50]. Despite the low partial pressure of oxygen in the placenta, oxygen delivery to fetal tissues remains adequate due to the combined high ventricular output and the presence of fetal hemoglobin, which has a higher oxygen affinity than adult hemoglobin [50,55,56].…”
Section: Fetal Structural Adaptations: the Four Shunts In Fetal Circumentioning
confidence: 99%
“…It is a low resistance vascular bed, which promotes the fetalto-maternal exchange of deoxygenated blood under low pressure [3,50]. Despite the low partial pressure of oxygen in the placenta, oxygen delivery to fetal tissues remains adequate due to the combined high ventricular output and the presence of fetal hemoglobin, which has a higher oxygen affinity than adult hemoglobin [50,55,56].…”
Section: Fetal Structural Adaptations: the Four Shunts In Fetal Circumentioning
confidence: 99%
“…We reached the same conclusion in 2014, when we performed a prospective observational study on 46 matched pairs of umbilical artery and vein blood samples from the same cord, unclamped and clamped, respectively. 5 We observed that there were no significant differences on arterial pH, PO 2 , pCO 2 , SaO 2 or hemoglobin concentration (ctHb) between the samples obtained within 90 seconds from birth and the clamped one, analyzed immediately after the previous sampling. Conversely, the venous SaO 2 , ctHb, and BE were significantly different between unclamped and clamped cord, although pH, PO 2 , and pCO 2 were comparable.…”
Section: Is Pulsating Cord Blood Sampling a Suitable And Reliable Metmentioning
confidence: 74%
“…We reached the same conclusion in 2014, when we performed a prospective observational study on 46 matched pairs of umbilical artery and vein blood samples from the same cord, unclamped and clamped, respectively. 5 We observed that there were no significant differences on arterial pH, PO 2 , pCO 2 , SaO 2 or hemoglobin concentration (ctHb) between the samples obtained within 90 seconds from birth and the clamped one, analyzed immediately after the previous sampling. Conversely, the venous SaO 2 , ctHb, and BE were significantly different between unclamped and clamped cord, although pH, PO 2 , and pCO 2 were comparable.According to this evidence, we validated for the first time the reliability of pulsating cord blood sampling compared with the standard clamped technique, and we proposed a modified method for blood sampling from the unclamped pulsating cord, allowing the sampling of the umbilical arterial vessels as well as the DCC, essential for placental transfusion.…”
mentioning
confidence: 74%
“…Different blood sampling procedures were practiced at vaginal delivery at our two maternity units: in Lund the cord vessels were routinely punctured promptly after birth by an assistant nurse without clamping the cord, whereas in Malmö the cord was double‐clamped by the midwife and blood collected later. The clamping or not clamping procedures make no difference per se in blood gas values as long as the samples are taken promptly, but for a busy midwife the clamping might be delayed. The technique used in Lund then resulted in a better quality of samples, with an additional bonus of allowing more blood to stream from the placenta to the newborn.…”
Section: Discussionmentioning
confidence: 99%