2018
DOI: 10.3384/ecp17142667
|View full text |Cite
|
Sign up to set email alerts
|

Blood Flow in the Abdominal Aorta Post 'Chimney' Endovascular Aneurysm Repair

Abstract: Aortic aneurysms are a main death cause in the elderly population throughout the western world. In recent years, more aneurysm repairs are performed endovascularly using stent grafts (SGs) inserted into the aneurysm site through the arterial system (minimally invasive). In this study, we analyze the hemodynamics in an aneurysmatic abdominal aorta (AAA) endovascularly repaired by a stent graft (SG) system using the chimney technique. Computational fluid dynamics (CFD) is employed to study models of a healthy ao… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
2
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 14 publications
0
2
0
Order By: Relevance
“…[19][20][21][22]. Other studies dealt with the qualitative relationship of geometric parameters with the DF [12][13][14][15][16][17], proposing hypotheses linking geometric parameters and DF but not quantitatively. It can still be seen that the DF values obtained in this study (3-7 N) are in good agreement with other studies [19,21,24,25,33] and more.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…[19][20][21][22]. Other studies dealt with the qualitative relationship of geometric parameters with the DF [12][13][14][15][16][17], proposing hypotheses linking geometric parameters and DF but not quantitatively. It can still be seen that the DF values obtained in this study (3-7 N) are in good agreement with other studies [19,21,24,25,33] and more.…”
Section: Discussionmentioning
confidence: 99%
“…Computational mechanics models can assist in accurately assessing the artery's condition after SG insertion [9][10][11]. The effect of different geometric parameters on EVAR results was previously investigated using numerical methods, including parameters such as chimney length [12,13], SG oversizing, aortic neck calcification [14], aneurysm neck angle [15] and SG bifurcation geometry [16,17]. Displacement force was calculated in computational fluid dynamics (CFD) studies, with both representative anatomies [18,19] and patient-specific geometries [20][21][22].…”
Section: Introductionmentioning
confidence: 99%
“…As discussed above, after the treatment of AAPs, the morphologies of the aortic arch change significantly, which alters the existing flows. This provides a clue for the assessment of different treatment approaches before operation [13,20,22,23,26,28].…”
Section: Discussionmentioning
confidence: 99%
“…While the blood flow field has important physiological meanings, it is attractive to extract an "ideal" structure from real tissues to study the effects of the predominant structure characteristics only [26,27]. This approach is significant for the understanding of typical flow patterns in tissues, such as secondary flow and helical flow.…”
Section: Introductionmentioning
confidence: 99%