1986
DOI: 10.1016/s0140-6736(86)92111-2
|View full text |Cite
|
Sign up to set email alerts
|

Blood Donor Sera With False-Positive Western Blot Reactions to Human Immunodeficiency Virus

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

2
28
0

Year Published

1987
1987
1991
1991

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 93 publications
(30 citation statements)
references
References 5 publications
2
28
0
Order By: Relevance
“…The band patterns identifed by Western blot in samples from donors who were reported as indeterminate were stable during the follow-up period. This is in line with findings by others [2,10,11] who concluded that such donors are prob ably not infected with HIV. Six donors were identified as being positive for HIV antibodies, and the resulting rates of carriers of HIV in Saudi national donors as well as in ex patriate donors were of a magnitude comparing favorably with figures presented by others [2].…”
supporting
confidence: 93%
“…The band patterns identifed by Western blot in samples from donors who were reported as indeterminate were stable during the follow-up period. This is in line with findings by others [2,10,11] who concluded that such donors are prob ably not infected with HIV. Six donors were identified as being positive for HIV antibodies, and the resulting rates of carriers of HIV in Saudi national donors as well as in ex patriate donors were of a magnitude comparing favorably with figures presented by others [2].…”
supporting
confidence: 93%
“…4 The Abbott CEIA uses p24 and gp41 antigens that have been produced by recombinant DNA technology. Because of this, there is little danger of cross reactivity with normal cellular components.…”
Section: Discussionmentioning
confidence: 99%
“…nitrocellulose. It seems likely that the latter technique is not optimally sensitive, moreover, false p24gag reactivity was found in individuals at low risk for AIDS, with no signs of HIV infection [15,16]. sera were found to have antibodies solely to gp 120/41 ( fig.…”
Section: Discussionmentioning
confidence: 99%
“…These evaluations have shown that, while some assays need to be refined, others offer the accuracy required for a satisfactory anti-HIV screening [13,14]. However, sever al reports have shown that isolated p24 reactivity in immunoblot can persist for years in individuals at low risk for AIDS, without signs of HIV infection [15,16],…”
mentioning
confidence: 99%