2020
DOI: 10.1016/j.jtemb.2019.09.005
|View full text |Cite
|
Sign up to set email alerts
|

Blood and plasma titanium levels associated with well-functioning hip implants

Abstract: Background: Hip implants are usually manufactured from cobalt-chromium and titanium alloys. As the implants wear and corrode, metal debris is released into the surrounding tissue and blood, providing a potential biomarker for their function. Whilst there are laboratory reference levels for blood cobalt and chromium in patients with well and poorly functioning hip implants, there are no such guidelines for titanium. This is despite the increasing use of titanium implants worldwide. Patients and methods: We recr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
21
0
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 29 publications
(22 citation statements)
references
References 40 publications
0
21
0
1
Order By: Relevance
“…In the context of joint arthroplasty, baseline titanium levels in patients who underwent THA have only recently been explored. In one series of 95 patients undergoing THA, Swiatkowska et al report a mean plasma titanium level of 2.5 micrograms/L to be indicative of a well-functioning implant at 8.5-year follow-up [15]. Savarino et al similarly report an upper limit of normal for serum titanium in these patients to be 4.5 mcg/L at 10 years and 5.1 mcg/L at 2-to 7year follow-up, respectively [16,17].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…In the context of joint arthroplasty, baseline titanium levels in patients who underwent THA have only recently been explored. In one series of 95 patients undergoing THA, Swiatkowska et al report a mean plasma titanium level of 2.5 micrograms/L to be indicative of a well-functioning implant at 8.5-year follow-up [15]. Savarino et al similarly report an upper limit of normal for serum titanium in these patients to be 4.5 mcg/L at 10 years and 5.1 mcg/L at 2-to 7year follow-up, respectively [16,17].…”
Section: Discussionmentioning
confidence: 99%
“…In one series of 95 patients undergoing THA, Swiatkowska et al. report a mean plasma titanium level of 2.5 micrograms/L to be indicative of a well-functioning implant at 8.5-year follow-up [ 15 ]. Savarino et al.…”
Section: Discussionmentioning
confidence: 99%
“…Most studies agree on the level of titanium between the ranges of 50-150 µg/kg although in our study and for the reasons alluded to above, the levels are much higher even in the unoperated control group. We can only compare the levels of the printed implant group to that the gold standard milled implant group as a measure of safety [86][87][88].…”
Section: Discussionmentioning
confidence: 99%
“…As an additional consideration, there is evidence of titanium debris being released from the devices due to the failure modes described above [4]. It is proposed that measures of titanium levels in blood samples from MAGEC patients may be a useful additional monitoring tool if it is practically possible and the appropriate collection, storage and analysis protocols can be utilised without impacting any resources required for the management of the pandemic [5]. This, however, requires further research to better understand the sensitivity and specificity of this measure.…”
Section: Determining Any Adverse Impact Of End-cap Separation or Othementioning
confidence: 99%