2008
DOI: 10.1093/europace/eun269
|View full text |Cite
|
Sign up to set email alerts
|

Bizarre case of migration of a retained epicardial pacing wire

Abstract: A 71-year-old woman, who had undergone mitral valve replacement procedure 2 years previously, presented with aortic and mitral prosthetic valve endocarditis. Preoperative examination demonstrated a wire-like structure coursing from the aortic bulb to the right carotid artery. The wire-like structure was removed during the mitral and aortic valve reoperation, and identified as an epicardial pacing wire, which was placed during the patients' first mitral valve operation. We suspect that the contaminated pacing w… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0
3

Year Published

2011
2011
2020
2020

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 19 publications
(16 citation statements)
references
References 4 publications
0
13
0
3
Order By: Relevance
“…10 The neurointerventional and cardiac literature also includes several reports of foreign bodies, including epicardial pacing wires, catheter tips, and detachable balloons. 1,3,6,8,11 Given the size of foreign objects relative to vessel caliber, most objects embolize into the distal ICA and middle cerebral artery (MCA) branches. It is exceedingly rare for a foreign body to become lodged in the CCA because of the larger size of that artery.…”
Section: Discussionmentioning
confidence: 99%
“…10 The neurointerventional and cardiac literature also includes several reports of foreign bodies, including epicardial pacing wires, catheter tips, and detachable balloons. 1,3,6,8,11 Given the size of foreign objects relative to vessel caliber, most objects embolize into the distal ICA and middle cerebral artery (MCA) branches. It is exceedingly rare for a foreign body to become lodged in the CCA because of the larger size of that artery.…”
Section: Discussionmentioning
confidence: 99%
“…Bu komplikasyonlar GEPT çıkartılması sırasında oluşabilir. Pacemaker teli çıkartılan hastalarda sonrasında aritmi, hemoraji-hemotorax ve tamponad, atriyal ve ventriküler yırtılma, SVG (safen ven greft) hasarı, koroner anastomoz bozuklukları, tel artığı yer değiştirmesi gibi ciddi komplikasyonlar olabilir (1)(2)(3)(4)(5). Komplikasyonların riski antikoagüle hastalarda ve re-do kardiyak cerrahide daha da artmaktadır (13).…”
Section: Discussionunclassified
“…Son yıllardaki yayınlarda GEPT kullanı-mı, nadir de olsa hemoraji ve kardiyak tamponad, atriyal ve ventriküler yırtılma gibi komplikasyonların yanında, pacemaker telinin çıkartılması sırasında gelişebilecek aritmi, telin çıkartılması sırasında veya sonrasında oluşabi-lecek kanama, tel bütünlüğünün kaybı nedeni ile yabancı cisim oluşması ve artık telin göçü gibi komplikasyonlarla ilişkilendirilmektedir (1)(2)(3)(4)(5)(6)(7)(8)(9)(10).…”
Section: Introductionunclassified
“…Une ablation tardive, notamment aprè s le septiè me jour postopé ratoire, est associé e à un risque accru d'ablation impossible des é lectrodes é picardiques [20], né cessitant souvent de les couper à la peau. Si ce geste paraît anodin, il expose né anmoins au risque de migration des é lectrodes retenues, qui peut survenir même quelques anné es aprè s [21,22].…”
Section: Ablation Des E´lectrodes E´picardiques Temporairesunclassified