1999
DOI: 10.3109/02841859909175589
|View full text |Cite
|
Sign up to set email alerts
|

Biventricular Diastolic Cardiac Function Assessed by MR flow Imaging using a Single Angulation

Abstract: Biventricular diastolic flow measurements can be obtained using one single angulation set parallel to the tricuspid valve.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2004
2004
2021
2021

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 14 publications
0
4
0
Order By: Relevance
“…In Fig. This illustrates that the 1-dir MV-flow method, although readily applied in clinical studies (Kroft and de Roos, 1999;Rebergen et al, 1996), is not recommended for accurate transvalvular MV-flow measurement. The area with regurgitant flow is clearly discriminated.…”
Section: Clinical Examplementioning
confidence: 99%
“…In Fig. This illustrates that the 1-dir MV-flow method, although readily applied in clinical studies (Kroft and de Roos, 1999;Rebergen et al, 1996), is not recommended for accurate transvalvular MV-flow measurement. The area with regurgitant flow is clearly discriminated.…”
Section: Clinical Examplementioning
confidence: 99%
“…32). Similar measurements can be performed by phasecontrast MRI (Mohiaddin et al 1990(Mohiaddin et al , 1991Mostbeck et al 1993;Galjee et al 1995;Kroft and de Roos 1999). An advantage of MRI over Doppler echocardiography is that MRI can quantify the flow through the entire valve area or vessel, in contrast to Doppler imaging, where flow and flow velocity are measured in a relatively small area of interest.…”
Section: Ventricular Inflow Patternsmentioning
confidence: 91%
“…With the introduction of cine 2D phase-contrast MRI in 1986 (124), flow imaging could become part of routine MRI. In the 1990s, several papers published in Acta Radiologica reported the use of phase-contrast velocity mapping in different applications such as measurement of aqueductal CSF flow (125,126), blood flow in the superior sagittal sinus (127), renal arteries (128), and biventricular diastolic flow (129). As documented in Acta Radiologica, velocity encoded phase contrast imaging has become an important part of cardiac MRI in congenital heart disease (130,131), and the technique can also be used for estimation of vessel wall shear stress (132,133).…”
Section: Flow Quantificationmentioning
confidence: 99%