2011
DOI: 10.1016/j.athoracsur.2011.02.081
|View full text |Cite
|
Sign up to set email alerts
|

Biventricular Continuous Flow VADs Demonstrate Diurnal Flow Variation and Lead to End-Organ Recovery

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2012
2012
2023
2023

Publication Types

Select...
4
3
2

Relationship

1
8

Authors

Journals

citations
Cited by 24 publications
(7 citation statements)
references
References 9 publications
0
7
0
Order By: Relevance
“…11 However, the HeartWare system does show a problem coming along with most biventricular assists: because the pulmonary vascular resistance is much smaller than the total peripheral resistance, it is necessary to narrow the RVAD outflow conduit from 10 to 5 mm to avoid overloading the pulmonary circulation. 12,13 In addition, the biventricular HeartWare needs 4 batteries and 2 controllers simultaneously, which increases the inconvenience for the patient. 12 Therefore, there are several reasons why we preferred the Jarvik 2000 system.…”
Section: Discussionmentioning
confidence: 99%
“…11 However, the HeartWare system does show a problem coming along with most biventricular assists: because the pulmonary vascular resistance is much smaller than the total peripheral resistance, it is necessary to narrow the RVAD outflow conduit from 10 to 5 mm to avoid overloading the pulmonary circulation. 12,13 In addition, the biventricular HeartWare needs 4 batteries and 2 controllers simultaneously, which increases the inconvenience for the patient. 12 Therefore, there are several reasons why we preferred the Jarvik 2000 system.…”
Section: Discussionmentioning
confidence: 99%
“…After completion of proximal anastomosis at the sinotubular junction level, the cross-clamp was released. Under the restored beating heart, an apical ring was sewn to the left ventricular apex with a running polypropylene suture and a HeartWare LVAD (Heartware International) was placed in the typical configuration [2]. The outflow graft was anastomosed to the aortic graft in an end-to-side manner.…”
Section: Case Reportmentioning
confidence: 99%
“…91, 92 These can be treated with RVAD or by switching to biventricular support. 89, 93 In addition to the 2 earlier devices, the HeartWare HVAD 94 and HeartMate II 95 have been used for long-term support of the RV. The TAH are, of course, another option.…”
Section: Mechanical Circulatory Support (Mcs)mentioning
confidence: 99%