2021
DOI: 10.11591/ijece.v11i5.pp3763-3771
|View full text |Cite
|
Sign up to set email alerts
|

Bipolar and unipolar schemes for confined band variable switching frequency PWM based inverter

Abstract: The single phase inverter performance through the unipolar and bipolar strategies has been previously analyzed based on the constant switching frequency pulse width modulation (CSFPWM). However, the confined band variable switching frequency PWM (CB-VSFPWM) is currently proposed as a new variable switching frequency PWM technique through unipolar strategy to facilitate the design of high order filter, to reduce the switching losses, and to reduce the current total harmonics distortion (THD) as well. To evaluat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 13 publications
(18 reference statements)
0
3
0
Order By: Relevance
“…π›₯𝑃 π‘Žπ‘,π‘™π‘œπ‘Žπ‘‘ = π›₯𝑃 𝑔𝑒𝑛,π‘Žπ‘ βˆ’ π›₯𝑃 π‘π‘œπ‘› (7) Droop in frequency happens due to change in AC load demand, which causes change in generating power at AC sub grid side which is verified by (8).…”
Section: Control Of Ilcs 31 Control Of Ilc-1 For 3-phasementioning
confidence: 86%
See 1 more Smart Citation
“…π›₯𝑃 π‘Žπ‘,π‘™π‘œπ‘Žπ‘‘ = π›₯𝑃 𝑔𝑒𝑛,π‘Žπ‘ βˆ’ π›₯𝑃 π‘π‘œπ‘› (7) Droop in frequency happens due to change in AC load demand, which causes change in generating power at AC sub grid side which is verified by (8).…”
Section: Control Of Ilcs 31 Control Of Ilc-1 For 3-phasementioning
confidence: 86%
“…A review paper discusses the power quality issues in bidirectional power flow in electric vehicle to grid [7]. To reduce the total harmonic distortion (THD) in a single-phase inverter a control technique confined band variable switching frequency pulse width modulation (CB-VSFPWM) is designed [8]. To extract maximum output power for a cluster MG, a modified reverse current flow method is proposed for radial system [9].…”
Section: Introductionmentioning
confidence: 99%
“…The voltage source inveter (VSI) circuit is presented in Figure 5 (b), this VSI is modulated with sinusoidal pulse-width-modulation (SPWM) technique. The fundamantal of SPWM technique had been presented in [27], [28]. Pure sinusoidal ac voltages, vg, are assumed as the voltage references in this simulation.…”
Section: System Level Simulation and Analysismentioning
confidence: 99%