2008
DOI: 10.2116/analsci.24.1399
|View full text |Cite
|
Sign up to set email alerts
|

Biphasic Electrospray Ionization for the Study of Interfacial Complexes

Abstract: Biphasic electrospray ionization (BESI) mass spectrometry is achieved by using a dual-channel microsprayer, where channels filled with different immiscible phases meet at the Taylor cone. Two types of interfacial complexation reactions have been studied: the interfacial complexation of aqueous lead ions by thioether crown molecules, and the interfacial complexation of an aqueous dipeptide by dibenzo-18-crown-6 as ionophore. The mass spectra also give valuable information on the stoichiometry of the complexatio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
23
0

Year Published

2009
2009
2022
2022

Publication Types

Select...
6
1

Relationship

6
1

Authors

Journals

citations
Cited by 17 publications
(25 citation statements)
references
References 50 publications
2
23
0
Order By: Relevance
“…In addition, this electrochemical oxidation has been observed in thioether crowns. 47 Transition metal ions catalyze the cysteine oxidation by generating reactive intermediates such as radicals. 9,10 Copper plays the role of electron carrier from thiol to oxygen where the complexation of copper(II) is the first step in the oxidation process.…”
Section: Kctcca Reactions With Zn 2+ and Other Reactionsmentioning
confidence: 99%
“…In addition, this electrochemical oxidation has been observed in thioether crowns. 47 Transition metal ions catalyze the cysteine oxidation by generating reactive intermediates such as radicals. 9,10 Copper plays the role of electron carrier from thiol to oxygen where the complexation of copper(II) is the first step in the oxidation process.…”
Section: Kctcca Reactions With Zn 2+ and Other Reactionsmentioning
confidence: 99%
“…[22][23][24] The dual-channel microsprayer (see the Tagging of Phosphopeptides Section) was used with reservoirs stuck on it or in a holder. [25,26] These devices were coupled to an ion trap mass spectrometer. These experimental descriptions give an idea about the setup and more details can be found in the cited literature or in the text.…”
Section: Methodsmentioning
confidence: 99%
“…4). [25] This microchip was fixed in a holder connected to a syringe pump that was able to hold two syringes to introduce two different solutions, e.g. water and 1,2-dichloroethane (DCE).…”
Section: Biphasic Esi: Study Of Interfacial Complexationmentioning
confidence: 99%
See 2 more Smart Citations