2005
DOI: 10.1016/j.trac.2004.11.008
|View full text |Cite
|
Sign up to set email alerts
|

Biosensing in high-performance chemical separations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2006
2006
2015
2015

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 20 publications
(6 citation statements)
references
References 131 publications
0
6
0
Order By: Relevance
“…Several immobilization techniques would be suitable for the purpose of this work, but due to the simplicity and the availability of the materials, the enzyme was immobilized onto a solid carrier which was kept in the reactor, separate from the detector, and which could be easily removed and replaced with fresh active enzyme [15]. As a support for enzyme immobilization, controlled pore glass is the most often used material [16,26]. The enzyme cross-linked with glutaraldehyde [27] showed good operational and storage stability (the enzyme was stable during one day of operation and the enzyme activity remained unchanged over 6 months of storage [17]).…”
Section: Inhibition (%) [Concentration Of Inhibitor (M)]mentioning
confidence: 99%
“…Several immobilization techniques would be suitable for the purpose of this work, but due to the simplicity and the availability of the materials, the enzyme was immobilized onto a solid carrier which was kept in the reactor, separate from the detector, and which could be easily removed and replaced with fresh active enzyme [15]. As a support for enzyme immobilization, controlled pore glass is the most often used material [16,26]. The enzyme cross-linked with glutaraldehyde [27] showed good operational and storage stability (the enzyme was stable during one day of operation and the enzyme activity remained unchanged over 6 months of storage [17]).…”
Section: Inhibition (%) [Concentration Of Inhibitor (M)]mentioning
confidence: 99%
“…The modified GCE was used as a working electrode. Area of working electrode used is 0.0707 cm 2 . Platinum wire and Ag/ AgCl were employed as an auxiliary and reference electrode respectively.…”
Section: Apparatusmentioning
confidence: 99%
“…Including well-designed electrophysiological and behavioural bioassays can provide essential additional information about bioactive compounds that cannot or can barely be detected in chemical analyses. In future studies biosensing techniques including electronic noses [203][204][205][206] might add to classical chemical analyses of…”
Section: Conclusion and Prospectsmentioning
confidence: 99%
“…Including well-designed electrophysiological and behavioural bioassays can provide essential additional information about bioactive compounds that cannot or can barely be detected in chemical analyses. In future studies biosensing techniques including electronic noses [203][204][205][206] might add to classical chemical analyses of HIPVs. If biologists, chemists and engineers join forces in this effort they will undoubtedly be able to fully unravel the fascinating world of chemically-mediated interactions between plants and their biotic environment.…”
Section: Conclusion and Prospectsmentioning
confidence: 99%