2021
DOI: 10.1109/jsen.2021.3068160
|View full text |Cite
|
Sign up to set email alerts
|

Biomimetic Tactile Sensor Array Based on Magnetostrictive Materials

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 23 publications
(11 citation statements)
references
References 29 publications
0
9
0
Order By: Relevance
“…Various grasp sensors have been proposed [ 46 , 47 , 48 , 49 , 50 , 51 , 52 , 53 , 54 , 55 , 56 , 57 , 58 , 59 , 60 , 61 , 62 , 63 , 64 , 65 ], including MEMS sensors [ 51 , 52 , 53 , 54 , 55 , 56 , 57 , 58 , 59 , 60 , 61 , 62 , 63 ], some of which were able to measure normal and tangential forces [ 58 , 59 , 60 ]. However, they had complex structures and required special detection circuits.…”
Section: Discussionmentioning
confidence: 99%
“…Various grasp sensors have been proposed [ 46 , 47 , 48 , 49 , 50 , 51 , 52 , 53 , 54 , 55 , 56 , 57 , 58 , 59 , 60 , 61 , 62 , 63 , 64 , 65 ], including MEMS sensors [ 51 , 52 , 53 , 54 , 55 , 56 , 57 , 58 , 59 , 60 , 61 , 62 , 63 ], some of which were able to measure normal and tangential forces [ 58 , 59 , 60 ]. However, they had complex structures and required special detection circuits.…”
Section: Discussionmentioning
confidence: 99%
“…where m 0 is the permeability of vacuum, H is the applied bias magnetic field strength, M s is the saturation magnetization, a is the nonhysteresis magnetization shape coefficient, a is the domain wall interaction coefficient, l s is the saturation magnetostriction coefficient of Galfenol wire and s is the stress (Gao et al, 2021). The geometric size of the wire cross section is much smaller than the axial geometric size, which is regarded as a simplified cantilever beam structure (Gao et al, 2021). According to Euler-Bernoulli beam structural dynamics theory, the relationship between the deflection of the cantilever beam and force is as follows:…”
Section: Measurement Model Of Depth Detectionmentioning
confidence: 99%
“…Based on the magnetic theory, B Gal in Galfenol wire is: where μ 0 is the permeability of vacuum, H is the applied bias magnetic field strength, M s is the saturation magnetization, a is the nonhysteresis magnetization shape coefficient, α is the domain wall interaction coefficient, λ s is the saturation magnetostriction coefficient of Galfenol wire and σ is the stress (Gao et al , 2021).…”
Section: Measurement Model Of Depth Detectionmentioning
confidence: 99%
See 1 more Smart Citation
“…One end of the cantilever beam was fixed, and the other end bent with force, resulting in a change of magnetic field. They successively used commercial Hall and TMR sensors to detect the change [ 49 , 72 , 105 , 106 ]. The sensitivity of this device is 126 mV/N in the range of 0–3 N.…”
Section: Classification and Developmentmentioning
confidence: 99%