2006
DOI: 10.1177/112070000601603s05
|View full text |Cite
|
Sign up to set email alerts
|

Biomechanics of a New Short-Stemmed Uncemented Hip Prosthesis: An In-Vitro Study in human Bone

Abstract: The migration pattern, cyclic motion, system stiffness and failure load of a new short-stemmed hip prosthesis were compared to a clinically successful shaft prosthesis during the initial loading phase. The influence of implant-sizing on mechanical stability was also investigated for the new stem, in particular with relation to the bone quality. Prostheses were implanted in paired human femora and loaded cyclically up to 3515 cycles. Relative displacements between prosthesis and bone were measured using a 3D-ca… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
15
0
1

Year Published

2007
2007
2017
2017

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 27 publications
(16 citation statements)
references
References 12 publications
0
15
0
1
Order By: Relevance
“…Nie za ob ser wo wa no infek cji głę bo kich. Po dob ne wy ni ki le cze nia uzy ska li ba da cze z in nych ośrod ków [5,20,21,22,23].…”
Section: Discussionunclassified
“…Nie za ob ser wo wa no infek cji głę bo kich. Po dob ne wy ni ki le cze nia uzy ska li ba da cze z in nych ośrod ków [5,20,21,22,23].…”
Section: Discussionunclassified
“…Westphal et al report in an in vitro study that initial cyclic motion of the Proxima (DePuy, Warsaw, IN) shortstemmed prosthesis is similar to that for a clinically successful Summit (DePuy, Warsaw, IN) stemmed implant, and therefore, bony ingrowth with long-term consolidation can be expected [ 88 ] . The Proxima implant tended to migrate more than the longer shaft prosthesis in the initial phase.…”
Section: Conservative Hip Prosthesis: Short Stemless Metaphysis Loadmentioning
confidence: 97%
“…Large migration and cyclic motion are related to poor bone quality in the Proxima prosthesis. Westphal et al conclude that only patients with good bone quality should be considered for short-stemmed devices [ 88 ] .…”
Section: Conservative Hip Prosthesis: Short Stemless Metaphysis Loadmentioning
confidence: 99%
See 1 more Smart Citation
“…The available short stems differ in designs and outcomes [5]. Short stems are categorized into four groups: Type 1 femoral neck only, Type 2 calcar loading, Type 3 lateral flare calcar loading, and Type 4 shortened tapered.…”
Section: Introductionmentioning
confidence: 99%