2023
DOI: 10.3389/fbioe.2023.1143575
|View full text |Cite
|
Sign up to set email alerts
|

Biomechanical study of internal fixation methods for femoral neck fractures based on Pauwels angle

Abstract: Objective: To select the most appropriate internal fixation method based on the Pauwels angle, in order to provide a new concept for clinical accurate treatment of femoral neck fractures (FNFs).Methods: FNFs models of Pauwels 30°; 40°; 50°; 60° were created respectively. For Pauwels ≤ 50°, 1, 2 and 3 Cannulated Compression Screws (CCS) and Porous Tantalum Screws (PTS) were used to fix the fracture for the models. For Pauwels 60°, 3CCS and Medial Buttress Plate (MBP) combined with 1, 2 and 3CCS were used to fix… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
10
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(11 citation statements)
references
References 29 publications
(24 reference statements)
1
10
0
Order By: Relevance
“…Since Dr Smith-Petersen, an American physician, invented trifin screws for treating femoral neck fractures in 1931, femoral neck internal fixation surgical devices have been rapidly developed over the decades, and various internal fixation devices such as cannulated screws, DHS, proximal femoral locking plate, percutaneous compression plate, medial buttress plate, and FNS have been invented are used in clinical practice to this day. Among them, the novel FNS has obvious biomechanical advantages and can support the fracture in multi-axial direction, with excellent anti-rotation and anti-shortening properties, with significant clinical efficacy (15)(16)(17)(18)(19). However, in China, limited by unbalanced economic development, cannulated screw internal fixation is still the most important surgical method, especially in the vast Central and Western regions and primary hospitals.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Since Dr Smith-Petersen, an American physician, invented trifin screws for treating femoral neck fractures in 1931, femoral neck internal fixation surgical devices have been rapidly developed over the decades, and various internal fixation devices such as cannulated screws, DHS, proximal femoral locking plate, percutaneous compression plate, medial buttress plate, and FNS have been invented are used in clinical practice to this day. Among them, the novel FNS has obvious biomechanical advantages and can support the fracture in multi-axial direction, with excellent anti-rotation and anti-shortening properties, with significant clinical efficacy (15)(16)(17)(18)(19). However, in China, limited by unbalanced economic development, cannulated screw internal fixation is still the most important surgical method, especially in the vast Central and Western regions and primary hospitals.…”
Section: Discussionmentioning
confidence: 99%
“…- ---------------------------------------------------------------------------------- shown that inverted triangular distribution has theoretically strong biomechanical properties and is the 'gold standard' for treatment with three cannulated screws (12,18,20,21). However, it must be emphasized that inverted triangular distribution has numerous shortcomings and limitations as well (15,16,(22)(23)(24).…”
Section: Anesthesiamentioning
confidence: 99%
See 1 more Smart Citation
“…6B). [140][141][142][143][144][145] Alternatively, the combination of COFs with other materials could enhance their performance in PEC detection platforms by providing more reactive sites for the determination of target environmental contaminants. In a study by Wang et al, a heterostructure was formed between TiO 2 NTAs and F-COFs through a simple hydrothermal method (Fig.…”
Section: Covalent Organic Frameworkmentioning
confidence: 99%
“…The vertical distance from the distal point of the fracture line to the tibial plateau is 40mm. [8] Fig. 1 The steps of finite element analysis…”
Section: Modelmentioning
confidence: 99%