2020
DOI: 10.1007/s11517-020-02149-1
|View full text |Cite
|
Sign up to set email alerts
|

Biomechanical influence of anchorages on orthodontic space closing mechanics by sliding method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(7 citation statements)
references
References 33 publications
0
7
0
Order By: Relevance
“…All patients were treated with pre-adjusted MBT appliances using 0.022″ × 0.028″ slot brackets (3 M Unitek, Monrovia, CA, USA). To reduce sliding friction, the second molars were not bonded until extraction space closure [ 16 ]. After the initial alignment, miniscrews 1.7 mm in diameter and 8.0 mm in length (Ortho Easy, Forestadent, Pforzheim, Germany) were placed in the interradicular area between the second premolars and maxillary first molars, at 8 mm above the arch wire; all procedures were performed by the same operator.…”
Section: Methodsmentioning
confidence: 99%
“…All patients were treated with pre-adjusted MBT appliances using 0.022″ × 0.028″ slot brackets (3 M Unitek, Monrovia, CA, USA). To reduce sliding friction, the second molars were not bonded until extraction space closure [ 16 ]. After the initial alignment, miniscrews 1.7 mm in diameter and 8.0 mm in length (Ortho Easy, Forestadent, Pforzheim, Germany) were placed in the interradicular area between the second premolars and maxillary first molars, at 8 mm above the arch wire; all procedures were performed by the same operator.…”
Section: Methodsmentioning
confidence: 99%
“…In this study, a certain distributed point on the occlusal surface of each tooth was selected for concentrate loading [ 17 ], and the chewing cycle was simplified to vertical loading and oblique loading. Under loading conditions, the edge of the mandible was fixed to prevent the jaw from displacement in the X, Y and Z directions [ 13 , 15 ] (Fig. 3 ).…”
Section: Methodsmentioning
confidence: 99%
“…All materials were considered linear-elastic, isotropic and homogeneous [10][11][12][13][14][15][16]. The applied material properties (elastic modulus and Poisson's ratio) were obtained from the literature (Table 2).…”
Section: Experimental Preset Conditionsmentioning
confidence: 99%
See 1 more Smart Citation
“…In addition, they present high fracture resistance and low propensity to osseointegration due to the grade V titanium alloy (Ti-6AI-4V) which they are made from [12]. The mini orthodontic implant was also considered an option to obtain maximum anchorage during anchorage loss [13].…”
Section: Introductionmentioning
confidence: 99%