2002
DOI: 10.1097/00003086-200212000-00035
|View full text |Cite
|
Sign up to set email alerts
|

Biomechanical Evaluation of the Proximal Femoral Nail

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
52
0
2

Year Published

2005
2005
2023
2023

Publication Types

Select...
8
1
1

Relationship

1
9

Authors

Journals

citations
Cited by 56 publications
(55 citation statements)
references
References 2 publications
1
52
0
2
Order By: Relevance
“…When the hip pin was 10 mm shorter than the lag screw, the percentage of the total load carried by the hip pin ranged from 8 to 39% (mean, 21%) 18 ; no cut-out of the femoral head and no unacceptable implant or fracture displacement were observed. 8 In our study, the hip pin was 10 to 15 mm shorter than the lag screw, and this may have prevented overloading the hip pin and cut-out in all cases. Unstable A2 fractures should be initially reduced to a slightly valgus position during PFN surgery, because the neck-shaft angle would decrease during the first 6 postoperative weeks.…”
Section: Discussionmentioning
confidence: 67%
“…When the hip pin was 10 mm shorter than the lag screw, the percentage of the total load carried by the hip pin ranged from 8 to 39% (mean, 21%) 18 ; no cut-out of the femoral head and no unacceptable implant or fracture displacement were observed. 8 In our study, the hip pin was 10 to 15 mm shorter than the lag screw, and this may have prevented overloading the hip pin and cut-out in all cases. Unstable A2 fractures should be initially reduced to a slightly valgus position during PFN surgery, because the neck-shaft angle would decrease during the first 6 postoperative weeks.…”
Section: Discussionmentioning
confidence: 67%
“…Although complication rates remain low, cut-out of either screw is a serious complication, which can lead to revision surgery and related morbidity. When the hip pin was 10mm shorter than lag screw, the percentage of the total load carried by the hip pin ranged from 8-39% (mean 21%) [11,12] . Unstable A2 fractures should be initially reduced to a slightly valgus position during PFN surgery, because the neck-shaft angle would decrease during the first 6 postoperative weeks.…”
Section: Discussionmentioning
confidence: 99%
“…Incidence of cut-out of lag screw is controversial because many authors have reported cut-out more with DHS while others have reported it more with the PFN. Schipper et al [18] have reported a cut out rate of 6.6% with gamma nail and 6.9% with PFN. Simmermacher et al [16] have not reported any case of post operative of later fracture of femur with DHS while Radford et al [29] have shown fracture in 1.0% operative fracture of femur and 3.0% cut out with DHS.…”
Section: Resultsmentioning
confidence: 97%