2023
DOI: 10.1016/j.heliyon.2023.e15312
|View full text |Cite
|
Sign up to set email alerts
|

Biomechanical evaluation of abutment stability in morse taper implant connections in different times: A retrospective clinical study compared with an in vitro analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
0
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 31 publications
0
0
0
Order By: Relevance
“…In our study, abutments of similar heights were used, with a difference of 1 mm between the abutments in group A and the abutments in groups B and C. However, when straight abutments were compared with angled abutments, angled abutments had lower stability values measured by RFA [27], corroborating our results. On the other hand, when we compare the results obtained in this study with the results recently published by our research group, we observe a proximity in the measured stability values after the application of cyclic loads [18]. The friction in the conical connections is responsible for the stability of the abutments.…”
Section: Plos Onesupporting
confidence: 75%
See 1 more Smart Citation
“…In our study, abutments of similar heights were used, with a difference of 1 mm between the abutments in group A and the abutments in groups B and C. However, when straight abutments were compared with angled abutments, angled abutments had lower stability values measured by RFA [27], corroborating our results. On the other hand, when we compare the results obtained in this study with the results recently published by our research group, we observe a proximity in the measured stability values after the application of cyclic loads [18]. The friction in the conical connections is responsible for the stability of the abutments.…”
Section: Plos Onesupporting
confidence: 75%
“…One of the main features of the Ideale abutment is the ability to receive both screw-retained and cemented crowns, as it has an internal thread on the upper part like a multi-unit abutment, which makes it possible to use this sensor to measure stability [13,18]. Then, after completion of cyclic loading, all loaded and unloaded specimens were evaluated for abutment stability using the Osstell Mentor device (Integration Diagnostics AB, Go ¨teborg, Sweden).…”
Section: Stability Measurementmentioning
confidence: 99%