2020
DOI: 10.1007/s13239-020-00469-9
|View full text |Cite
|
Sign up to set email alerts
|

Biomechanical Assessment of Bicuspid Aortic Valve Phenotypes: A Fluid–Structure Interaction Modelling Approach

Abstract: assessment of bicuspid aortic valve phenotypes: a fluid-structure interaction modelling approach', Cardiovascular Engineering and Technology.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
10
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 11 publications
(12 citation statements)
references
References 83 publications
(144 reference statements)
1
10
1
Order By: Relevance
“…Geometric orifice area characterizes the dynamic changes of the physical orifice area of the aortic valve, and the maximum value appeared at the moment when the pressure difference was greatest ( t = 0.05 s). In this study, the maximum GOA of the TAV and BAV models during systole was lower than the GOA reported in similar studies ( Cao and Sucosky, 2017 ; de Oliveira et al, 2020 ), which might be due to the differences in the models. Diameter of the aortic annulus used in this article was 23 mm, which was a smaller annulus size.…”
Section: Discussioncontrasting
confidence: 89%
See 4 more Smart Citations
“…Geometric orifice area characterizes the dynamic changes of the physical orifice area of the aortic valve, and the maximum value appeared at the moment when the pressure difference was greatest ( t = 0.05 s). In this study, the maximum GOA of the TAV and BAV models during systole was lower than the GOA reported in similar studies ( Cao and Sucosky, 2017 ; de Oliveira et al, 2020 ), which might be due to the differences in the models. Diameter of the aortic annulus used in this article was 23 mm, which was a smaller annulus size.…”
Section: Discussioncontrasting
confidence: 89%
“…All the FSI processes were completed using explicit solver provided by LS-DYNA R11.1.0 (LSTC, Livermore, CA, United States and ANSYS Inc., Canonsburg, PA, United States). The effectiveness of this software in heart valves problems had been widely confirmed in previous studies ( de Oliveira et al, 2020 ; Luraghi et al, 2020 ). Two cardiac cycles (The duration of single cycle was set to 0.8 s) were considered in the calculation to eliminate the effect of the initial instability.…”
Section: Methodssupporting
confidence: 58%
See 3 more Smart Citations