2020
DOI: 10.1007/978-3-030-60124-9_2
|View full text |Cite
|
Sign up to set email alerts
|

Biomechanical and Tribological Aspects of Orthopaedic Implants

Abstract: Orthopaedic and dental implant treatments have allowed to enhance the quality of life of millions of patients. Total hip/knee arthroplasty is a surgical replacement of the hip/knee joint with an artificial prosthesis. The aim of joint replacement surgery is to relieve pain improve function, often for sufferers of osteoarthritis, which affects around a third of people aged over fifty. Nowadays, total hip and knee replacement (THR) surgeries are considered routine procedures with generally excellent outcomes. Gi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 87 publications
0
3
0
Order By: Relevance
“…92 A book chapter by Irene Gotman reviews the topic of wear debris, osteolysis, and aseptic loosening of orthopedic implants in detail. 93 Last, in commercial Ti implants with surface coatings, Zimmer Biomet manufactured femoral stems with porous plasma spray (PPS) Ti-coated Taperloc hip femoral stem demonstrated long-term osseointegration and survival with low 7.8% revisions required due to aseptic loosening, osteolysis, infections, peri-prosthetic fractures, etc. after a 25-year follow-up.…”
Section: Surface Coatings For Osseointegrationmentioning
confidence: 99%
See 1 more Smart Citation
“…92 A book chapter by Irene Gotman reviews the topic of wear debris, osteolysis, and aseptic loosening of orthopedic implants in detail. 93 Last, in commercial Ti implants with surface coatings, Zimmer Biomet manufactured femoral stems with porous plasma spray (PPS) Ti-coated Taperloc hip femoral stem demonstrated long-term osseointegration and survival with low 7.8% revisions required due to aseptic loosening, osteolysis, infections, peri-prosthetic fractures, etc. after a 25-year follow-up.…”
Section: Surface Coatings For Osseointegrationmentioning
confidence: 99%
“…Another important consideration in the context of osseointegration is the stiffness (Young’s modulus) mismatch of the cortical and cancellous bone (4–30 GPa) with Ti and Ti6Al4V alloy (∼110 GPa) that causes stress shielding, bone resorption, and implant loosening . A book chapter by Irene Gotman reviews the topic of wear debris, osteolysis, and aseptic loosening of orthopedic implants in detail . Last, in commercial Ti implants with surface coatings, Zimmer Biomet manufactured femoral stems with porous plasma spray (PPS) Ti-coated Taperloc hip femoral stem demonstrated long-term osseointegration and survival with low 7.8% revisions required due to aseptic loosening, osteolysis, infections, peri-prosthetic fractures, etc.…”
Section: Hard and Soft Tissue Integration Around Percutaneous Bone-an...mentioning
confidence: 99%
“…Studies show that UHMWPE wear is the main reason behind aseptic loosening in orthopedic implants. 9 Friction between the contacting articulating surfaces can be reduced by minimizing adhesion and also by minimizing normal and shear stresses, which can be achieved through ultra-high polishing. 10 According to fundamental tribological investigation, wear of UHMWPE increases with an increase in counterface or femoral component surface roughness.…”
Section: Introductionmentioning
confidence: 99%