2013
DOI: 10.1016/j.medengphy.2013.04.007
|View full text |Cite|
|
Sign up to set email alerts
|

Biomechanical analysis of different types of pedicle screw augmentation: A cadaveric and synthetic bone sample study of instrumented vertebral specimens

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

5
50
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
5
4

Relationship

1
8

Authors

Journals

citations
Cited by 62 publications
(57 citation statements)
references
References 30 publications
5
50
0
Order By: Relevance
“…1,7,14,17,21,24 The main difference among these FPSs is the number of side perforations. Regardless of the different number of perforations, the pullout strength of PMMA-augmented FPSs is greater than that of nonaugmented conventional screws 3,5,9,10,12,26 or cannulated screws 8,16,18 in the osteoporotic condition. In the present study, compared with the nonaugmented CPS group, FPS-A1.0, 1.5, and 2.0 achieved 137%, 207%, and 265% increased pullout strengths, respectively, and FPS-B1.0, 1.5, and 2.0 achieved 166%, 232%, and 269% increased pullout strengths, respectively.…”
Section: Discussionmentioning
confidence: 95%
See 1 more Smart Citation
“…1,7,14,17,21,24 The main difference among these FPSs is the number of side perforations. Regardless of the different number of perforations, the pullout strength of PMMA-augmented FPSs is greater than that of nonaugmented conventional screws 3,5,9,10,12,26 or cannulated screws 8,16,18 in the osteoporotic condition. In the present study, compared with the nonaugmented CPS group, FPS-A1.0, 1.5, and 2.0 achieved 137%, 207%, and 265% increased pullout strengths, respectively, and FPS-B1.0, 1.5, and 2.0 achieved 166%, 232%, and 269% increased pullout strengths, respectively.…”
Section: Discussionmentioning
confidence: 95%
“…Recently, FPSs with different designs have been studied in vitro [3][4][5][8][9][10]12,16,18,26 and in vivo. 1,7,14,17,21,24 The main difference among these FPSs is the number of side perforations.…”
Section: Discussionmentioning
confidence: 99%
“…Screw pull-out studies using human cadaveric tissues report a wide range of values from 102 to 1,741 N (15,26,28,(31)(32)(33)(34). Similarly, screw pull-out with the calf model reports values from 747 to 7,300 N, depending on treatment (30,35).…”
Section: Comparison To Existing Literaturementioning
confidence: 99%
“…They also found that the failure rate of CPS can be reduced by reducing the number of the radial hole. Although the effect of parameters of the radial holes (diameter and position of radial holes) on failure rate of CPS have been proof experimentally and numerically by several researchers [4][5][6][7][8][9][10], the optimum position and diameter of radial holes still becoming one of the gap in this research field. Thus, the aim of this paper is to propose the design optimization of cannulated pedicle screw which focuses more on optimization of diameter and position of radial holes.…”
Section: Introductionmentioning
confidence: 99%