Biological thermodynamic data for the calibration of differential scanning calorimeters: heat capacity data on the unfolding transition of ribonuclease a in solution

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
32
0

Year Published

1990
1990
2008
2008

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 46 publications
(32 citation statements)
references
References 16 publications
0
32
0
Order By: Relevance
“…However, On the other hand, net long-term drift in tempera-Origin data analysis software contains a Response butture is virtually zero when the shield is thermostatted. ton located on the graphic template, which when actiAlthough the improvements in adiabaticity consider-vated quickly removes small amounts of response-time ably reduce the long-term temperature drift when us-broadening for any of the four response times using ing the zero-scan-rate mode, it is still significant (Ç0.03 standard methods (2). This postrun capability somedeg/h at 65ЊC).…”
Section: Improvements In Adiabaticitymentioning
confidence: 97%
See 1 more Smart Citation
“…However, On the other hand, net long-term drift in tempera-Origin data analysis software contains a Response butture is virtually zero when the shield is thermostatted. ton located on the graphic template, which when actiAlthough the improvements in adiabaticity consider-vated quickly removes small amounts of response-time ably reduce the long-term temperature drift when us-broadening for any of the four response times using ing the zero-scan-rate mode, it is still significant (Ç0.03 standard methods (2). This postrun capability somedeg/h at 65ЊC).…”
Section: Improvements In Adiabaticitymentioning
confidence: 97%
“…Fax: 413-586-0149. 2 Abbreviation used: DSC, differential scanning calorimeter. ously during operation and stored in computer memory Corp.).…”
mentioning
confidence: 99%
“…Differential Scanning Calorimetry-All DSC measurements were performed using a Hart 7707 DSC heat conduction scanning microcalorimeter as described by Schwarz and Kirchhoff (30). The Hart DSC consists of three removable vessels containing the protein solution and a fourth removable vessel containing just the buffer solution in an adiabatic enclosure.…”
Section: Methodsmentioning
confidence: 99%
“…It is also recommended that test solutions consisting of protein solutions that exhibit known transition enthalpies such as simple globular proteins like ribonuclease A [35], lysozyme [36], and lactoglobulin [37] be scanned to check the operating performance of the DSC. To evaluate the applicability of a protein test solution in checking the operating performance of different DSCs in different laboratories, samples of hen egg white lysozyme solutions were sent to six different international laboratories.…”
Section: Dsc Calibration and Test Proceduresmentioning
confidence: 99%