Biological and Technical Variables Affecting Immunoassay Recovery of Cytokines from Human Serum and Simulated Vaginal Fluid: A Multicenter Study

Abstract: The increase of proinflammatory cytokines in vaginal secretions may serve as a surrogate marker of unwanted inflammatory reaction to microbicide products topically applied for the prevention of sexually transmitted diseases, including HIV-1. Interleukin (IL)-1β and IL-6 have been proposed as indicators of inflammation and increased risk of HIV-1 transmission; however, the lack of information regarding detection platforms optimal for vaginal fluids and interlaboratory variation limit their use for microbicide e… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

5
128
1

Year Published

2008
2008
2023
2023

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 166 publications
(134 citation statements)
references
References 28 publications
5
128
1
Order By: Relevance
“…22 The multiplex kits can be custom made to fit the panel of cytokines selected for any study design. In preparation for the EMPRO Flora Study, a study investigating vaginal flora and mucosal characteristics in 28 young healthy Belgian women not using hormonal contraceptives, we performed a 27 BioPlex multiplex test run on samples from this same population to make a final selection for a multiplex panel (unpublished observation).…”
Section: Issues With Measuring Soluble Factorsmentioning
confidence: 99%
“…22 The multiplex kits can be custom made to fit the panel of cytokines selected for any study design. In preparation for the EMPRO Flora Study, a study investigating vaginal flora and mucosal characteristics in 28 young healthy Belgian women not using hormonal contraceptives, we performed a 27 BioPlex multiplex test run on samples from this same population to make a final selection for a multiplex panel (unpublished observation).…”
Section: Issues With Measuring Soluble Factorsmentioning
confidence: 99%
“…Recovery more than 100% indicates that the measured values for a matrix were higher than the nominal value of the spike (Fichorova et al 2008). On the other hand, low level impurities which caused by the sample structure or presence of melamine under the detection limit, increase the recovery of methods.…”
Section: Resultsmentioning
confidence: 99%
“…multiplex bead assays or ELISA kits) used and possible interlaboratory variations. It should also be kept in mind that it would be logical not to compare the results that belong to one assay to another assay used in different studies (18).…”
Section: Figurementioning