2018
DOI: 10.1002/zaac.201800457
|View full text |Cite
|
Sign up to set email alerts
|

Bioinspired Trispyrazolylborato Nickel(II) Flavonolate Complexes and Their Reactivity Toward Dioxygen

Abstract: Aiming at structural and functional mimics of the active site of the Ni II containing quercetin-2,4-dioxygenase Ni II flavonolate complexes Tp*NiX [Tp* = hydrotris(3,5-dimethyl)pyrazolylborate, X = 3-hydroxy flavonolate (Fla), 3-hydroxy thioflavonolate (SFla), 3hydroxy selenoflavonolate (SeFla)] were synthesized and characterized by spectroscopic methods and X-ray crystallography. The complex Tp*NiFla reacts with O 2 via dioxygenation of bound flavonolate to

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 28 publications
(17 reference statements)
0
5
0
Order By: Relevance
“…ATR-infrared (IR) spectra were recorded on a Bruker alpha FTIR spectrometer in the region 4000−400 cm −1 using solid samples. Microanalyses were performed on a HEKAtech Euro EA 3000 elemental analyzer (we have frequently experienced that Tp complexes lead to C analysis, which are a little bit too low, while the other elements fit 33 ). The presence of dichloromethane in the elemental analysis samples was confirmed using 1 H NMR spectroscopy.…”
Section: ■ Conclusionmentioning
confidence: 99%
“…ATR-infrared (IR) spectra were recorded on a Bruker alpha FTIR spectrometer in the region 4000−400 cm −1 using solid samples. Microanalyses were performed on a HEKAtech Euro EA 3000 elemental analyzer (we have frequently experienced that Tp complexes lead to C analysis, which are a little bit too low, while the other elements fit 33 ). The presence of dichloromethane in the elemental analysis samples was confirmed using 1 H NMR spectroscopy.…”
Section: ■ Conclusionmentioning
confidence: 99%
“…ATR‐IR spectra were recorded with a Bruker alpha FTIR spectrometer in the region 4000–400 cm −1 . Microanalyses were performed with a HEKAtech Euro EA 3000 elemental analyzer (we have frequently experienced that Tp complexes lead to C analyses, which are a little bit too low, while the results for the other elements fit) [54] . UV‐vis spectra were obtained at variable temperatures with an Agilent 8453 UV‐vis spectrophotometer equipped with a Unisoku USP‐203‐A cryostat.…”
Section: Methodsmentioning
confidence: 99%
“…ATR‐IR spectra of solid samples were recorded with a Bruker alpha FTIR spectrometer in the region 4000–400 cm −1 . Microanalyses were performed with a HEKAtech Euro EA 3000 elemental analyzer (we have frequently experienced that Tp complexes lead to C analyses, which are a little bit too low, while the results for the other elements fit) [68] . UV‐vis spectra were obtained at variable temperatures with an Agilent 8453 UV‐vis spectrophotometer equipped with a Unisoku USP‐203‐A cryostat.…”
Section: Methodsmentioning
confidence: 99%