Bioimpedance spectroscopy technique: intra-, extracellular, and total body water

Abstract: The purpose of this study was to test the validity of a multiple frequency bioimpedance spectroscopy (BIS) technique that estimates extracellular fluid volume (ECV), intracellular fluid volume (ICV), and total body water (TBW). Thirteen healthy males (mean +/- SD: age, 23 +/- 3 yr; body mass, 80.6 +/- 14.7 kg) had their TBW and ECV measured by ingesting dilution tracers (7.27 g deuterium oxide, 1.70 g sodium bromide; blood samples at 0 and 4 h). ICV was calculated as TBW minus ECV. Impedance was measured (50-5… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
68
4
1

Year Published

1999
1999
2017
2017

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 83 publications
(77 citation statements)
references
References 21 publications
3
68
4
1
Order By: Relevance
“…16 participants' ZOE2 values increased from pre-to post-practice and 13 decreased, while 14 participants' ZOEW values increased from pre-to post-practice and 15 decreased ( Figure 11). Similar to several previous investigations, our findings indicate that bio-electrical impedance as used in this study is not a valid measure of post-exercise mild dehydration in a field environment (Armstrong et al 1997;O'Brien et al 1999;Koulmann et al 2000;O'Brien et al 2002;Carter et al 2004;Casa et al 2005;Cheuvront 2005). …”
Section: ) Pre-post-practice Comparisons Of Hydration Measuressupporting
confidence: 82%
See 2 more Smart Citations
“…16 participants' ZOE2 values increased from pre-to post-practice and 13 decreased, while 14 participants' ZOEW values increased from pre-to post-practice and 15 decreased ( Figure 11). Similar to several previous investigations, our findings indicate that bio-electrical impedance as used in this study is not a valid measure of post-exercise mild dehydration in a field environment (Armstrong et al 1997;O'Brien et al 1999;Koulmann et al 2000;O'Brien et al 2002;Carter et al 2004;Casa et al 2005;Cheuvront 2005). …”
Section: ) Pre-post-practice Comparisons Of Hydration Measuressupporting
confidence: 82%
“…electrode placement, side of body, posture, limb position, ambient temperature, skin temperature, hydration status, food and liquid intake, fluid shifts, sweating, and recency of exercise (Caton et al 1988;Roos et al 1992;Shirreffs and Maughan 1994;Gudivaka et al 1996;Armstrong et al 1997;Cheuvront 2005). In this current study, ambient temperature could not have been an error source because it did not change from pre-to post-practice measurements.…”
Section: Many Investigators Have Reported Factors That May Effect Biomentioning
confidence: 99%
See 1 more Smart Citation
“…Bioimpedance analysis models for calculation of extracellular resistance and prediction of whole body extracellular water volume have been validated using deuterium oxide [5,[26][27][28] and bromide dilution techniques. With bromide dilution, considered the gold standard for V ECF assessment, whole body V ECF is determined from bromide concentrations in blood plasma following solution ingestion [19,28].…”
Section: (1)mentioning
confidence: 99%
“…Differences in volume and electrolyte content affect conductance and resistance of the applied current (resistance is the inverse to conductivity). The bioelectrical impedance method utilizes the greater conductivity of fat free mass and the greater resistance of the fat mass in the determination of body composition [15,16].…”
Section: Introductionmentioning
confidence: 99%