2001
DOI: 10.1039/b009539g
|View full text |Cite
|
Sign up to set email alerts
|

Bioelectrocatalysis-based dihydrogen/dioxygen fuel cell operating at physiological pH

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
99
0

Year Published

2010
2010
2021
2021

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 152 publications
(101 citation statements)
references
References 26 publications
2
99
0
Order By: Relevance
“…These performance metrics were reproducibly observed throughout the 2-year operation of the MFC system 18 . The potentiostatic operation (S1), with the anodic potential controlled to þ 100 mV versus SHE allowed for the measurement of anodic microbial activity independent of system limitations 18,19 , resulted in a current density that was 8 times higher (550 mA m À 2 ) than that observed for the MFC condition, and the electron recovery efficiency was B50%. During the OC condition (S2) the anode electrode was disconnected from the cathode electrode and operated with zero current production and 0% electron recovery.…”
Section: Resultsmentioning
confidence: 99%
“…These performance metrics were reproducibly observed throughout the 2-year operation of the MFC system 18 . The potentiostatic operation (S1), with the anodic potential controlled to þ 100 mV versus SHE allowed for the measurement of anodic microbial activity independent of system limitations 18,19 , resulted in a current density that was 8 times higher (550 mA m À 2 ) than that observed for the MFC condition, and the electron recovery efficiency was B50%. During the OC condition (S2) the anode electrode was disconnected from the cathode electrode and operated with zero current production and 0% electron recovery.…”
Section: Resultsmentioning
confidence: 99%
“…Systems biology for electrogenic biofilms S Ishii et al system limitations, anode and cathode polarization curves were determined by linear sweep voltammetry (Tsujimura et al, 2001). The curves clearly showed that the cathode polarization strongly affected the whole MFC system polarization; however, the anode polarization curves showed that anodic limiting current densities significantly increased from around 0.1 mA cm À 2 to 0.3 mA cm À 2 during the 3-month operation in all MFCs (Figures 3a-d).…”
Section: Limiting Current Densitymentioning
confidence: 99%
“…In order to obtain anode polarization curves, an Ag/AgCl reference electrode (RE-5B, BASi) was placed in the side port of the reactors, and linear sweep voltammetry analyses were conducted using a potentiostat (Reference 600 or MultEchem System, Gamry) (Tsujimura et al, 2001;Ishii et al, 2008). The anode potential was swept from open-circuit anode potential to þ 300 mV vs SHE at a scan rate of 0.5 mV s À 1 and the corresponding anodic current was recorded.…”
Section: Polarization Analysesmentioning
confidence: 99%
“…[290] The first biofuel cell based on H 2 oxidation and O 2 reduction was reported late in 2001. [291] The enzyme for O 2 reduction was a BOD from Mv. H 2 oxidation was not realized by enzymes themselves but by whole cells of the sulfate reducing bacterium Desulfovibrio vulgaris Hildenborough (DvH), which is known to contain several Hases from different classes.…”
Section: H 2 /O 2 Biofuel Cells: a Short But Attractive Storymentioning
confidence: 99%