Bioelectrical impedance with different equations versus deuterium oxide dilution method for the inference of body composition in healthy older persons

Abstract: Abstract:Background: There is no consensus regarding the accuracy of bioimpedance for the determination of body composition in older persons. Objective: This study aimed to compare the assessment of lean body mass of healthy older volunteers obtained by the deuterium dilution method (reference) with those obtained by two frequently used bioelectrical impedance formulas and one formula specifically developed for a Latin-American population. Design: A cross-sectional study. Participants: Twenty one volunteers we… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
2
0
7

Year Published

2012
2012
2021
2021

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 10 publications
(9 citation statements)
references
References 14 publications
(11 reference statements)
0
2
0
7
Order By: Relevance
“…In addition, it is minimally invasive and can be used in any clinical situation. 6 Dual X-ray absorptiometry (DXA) assessment is considered to be a reference method for the evaluation of body composition. 7 However, it is often difficult to take centenarians to the reference center for the realization of the DXA, due to difficulties of locomotion.…”
Section: Introductionmentioning
confidence: 99%
“…In addition, it is minimally invasive and can be used in any clinical situation. 6 Dual X-ray absorptiometry (DXA) assessment is considered to be a reference method for the evaluation of body composition. 7 However, it is often difficult to take centenarians to the reference center for the realization of the DXA, due to difficulties of locomotion.…”
Section: Introductionmentioning
confidence: 99%
“…Some more sophisticated methods for assessment of body composition, such as the double X-ray absorptiometry 18 and the deuterium oxide 7 , are often not feasible for use in field studies due to their high costs and the need of specialized personnel for their analysis. Anthropometry is still the most widely used method, due to the low costs and simplicity.…”
Section: Discussionmentioning
confidence: 99%
“…Para isso, é importante adotar técnicas que sejam precisas para a avaliação da composição corporal, como é o caso do óxido de deutério ( 2 H 2 O) [6][7][8] . Apesar de ser muito acurada, o óxido de deutério ainda é pouco utilizado na prática clínica e apresenta custos elevados e métodos sofisticados de análise, como o espectrômetro de massa.…”
Section: N T R O D U ç ã Ounclassified
“…Alguns mé-todos mais sofisticados para estimar a composição corporal 7,26 , a exemplo da absorciometria por dupla emissão de raios X e do óxido de deutério, muitas vezes são inviáveis para estudo de campo devido ao seu alto custo e da necessidade de pessoas especializadas para sua análise 8 . O método antropométrico ainda é o mais usado pela sua facilidade e economia.…”
Section: I S C U S S ã Ounclassified