2021
DOI: 10.1097/mcc.0000000000000840
|View full text |Cite
|
Sign up to set email alerts
|

Bioelectric impedance analysis for body composition measurement and other potential clinical applications in critical illness

Abstract: Purpose of review Insight into body composition is of great value in the ICU. Bioelectric impedance analysis (BIA) is the most applicable bedside technique. However, bioimpedance has not been validated in the critically ill, and the interpretation of the measurements poses challenges. This review discusses the potential clinical applications of BIA and explores caveats and solutions to its use in the intensive care setting. Recent findings A correlation is repeatedly found … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
54
0
2

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 69 publications
(77 citation statements)
references
References 59 publications
1
54
0
2
Order By: Relevance
“…Henceforth, the software uses validated methods to estimate fat-free mass (FFM), soft lean mass (SLM), mineral mass, bone mineral content (BMC), percentage body fat (PBF), VFA, skeletal muscle mass (SMM), body cell mass (BCM) and protein mass, in addition to several ratios and segmental values. Fluid overload (FO) was calculated by subtracting a recalculated ECW based on a normal ECW/TBW ratio of 0.380 from the measured ECW (i.e., OH ¼ ECW measured e ((ICW Â 0.380)/0.620)), a method that is used in dialysis patients [1,2].…”
Section: Bia Measurementsmentioning
confidence: 99%
See 1 more Smart Citation
“…Henceforth, the software uses validated methods to estimate fat-free mass (FFM), soft lean mass (SLM), mineral mass, bone mineral content (BMC), percentage body fat (PBF), VFA, skeletal muscle mass (SMM), body cell mass (BCM) and protein mass, in addition to several ratios and segmental values. Fluid overload (FO) was calculated by subtracting a recalculated ECW based on a normal ECW/TBW ratio of 0.380 from the measured ECW (i.e., OH ¼ ECW measured e ((ICW Â 0.380)/0.620)), a method that is used in dialysis patients [1,2].…”
Section: Bia Measurementsmentioning
confidence: 99%
“…A PhA greater than 6 is assumed healthy, although the normal range varies with sex and age. Diminished cell count, membrane integrity and altered hydration status in critical illness leads to a decreased PhA, which has been shown to correlate with increased mortality, length of ward-, ICU-and hospital-stay, duration of mechanical ventilation and APACHE-II score in various diseases [2].…”
Section: Introductionmentioning
confidence: 99%
“…Unter Einbeziehung des Körpergewichts können über verschiedene Algorithmen die fettfreie Masse, Körperzellmasse und Fettmasse berechnet werden [ 81 , 82 ]. Diese Berechnungen sind jedoch bei Intensivpatient*innen weit weniger aussagekräftig als der gewichtsunabhängige, jedoch alters- und geschlechtsabhängige Phasenwinkel.…”
Section: Methoden Zur Bestimmung Des Ernährungszustandsunclassified
“…Inbody regards FFM and LBM as synonyms, defined as TBW minus non-essential storage fat mass (FM), corrected for hydration status through extracellular/total body water ratio [12]. In this definition, FFM/LBM includes essential fats, such as those stored in organs, the central nervous system and bone marrow.…”
Section: Definition Of Lean Body Massmentioning
confidence: 99%
“…The incorporated software then derives LBM through validated regression analyses based on a healthy reference population. BIA derived LBM (LBM BIA ) for calculating protein needs has substantial theoretical advantages over mathematical methods regarding body composition [12]. In addition, BIA measurements can be performed at the bedside, in contrast to other direct methods such as dual-energy X-ray absorptiometry.…”
Section: Introductionmentioning
confidence: 99%