2013
DOI: 10.1007/s10544-013-9781-9
|View full text |Cite
|
Sign up to set email alerts
|

Biocompatible TiO2 nanoparticle-based cell immunoassay for circulating tumor cells capture and identification from cancer patients

Abstract: We demonstrate the isolation of circulating tumor cells (CTCs) with a biocompatible nano-film composed of TiO2 nanoparticles. Due to the enhanced topographic interaction between nano-film and cancer cell surface, cancer cells (HCT116) spiked into PBS and healthy blood can be recovered from the suspension, whose efficiencies were respectively 80 % and 50 %. Benifit from the biocompatibility of this nano-film, in-situ culture of the captured cancer cells is also available, which provides an alternative selection… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
50
0

Year Published

2014
2014
2017
2017

Publication Types

Select...
7
3

Relationship

2
8

Authors

Journals

citations
Cited by 65 publications
(51 citation statements)
references
References 33 publications
1
50
0
Order By: Relevance
“…Oxides such as TiO 2 2 , SnO 2 3 and ZnO 1 can be used as sensing part in these devices. The biocompatibility of these materials has already been demonstrated by other research groups [4][5][6][7][8] , and they have been used as part of various types of biosensors.…”
Section: Introductionmentioning
confidence: 93%
“…Oxides such as TiO 2 2 , SnO 2 3 and ZnO 1 can be used as sensing part in these devices. The biocompatibility of these materials has already been demonstrated by other research groups [4][5][6][7][8] , and they have been used as part of various types of biosensors.…”
Section: Introductionmentioning
confidence: 93%
“…Captured cells were then stained with PE-labeled anti-CK, FITC-labeled anti-CD45 and DAPI. [26][27][28][29] Fluorescence microscopy was used to distinguish specifically captured CTCs (CK+/CD45-/DAPI+) from non-specifically immobilized WBCs (CK-/CD45+/DAPI+) by their fluorescence and larger size (CTCs: 10-30 µm; 1 WBCs, 15 µm) ( Figure 6A). CTC enumeration results are summarized in Figure 6B and Table 1.…”
Section: Sa-anti-epcam-flat Glass S a -A N T I -E P C A M F L A T G Lmentioning
confidence: 99%
“…And, we also compared the capture performance of anti-EpCAM coated CTC- BioT Chip with slex-AP coated CTC- BioT Chip using artificial blood (detailed in supporting information). PE-labeled anti-CK, FITC-labeled anti-CD45 and DAPI were introduced onto the CTC- BioT Chip for artificial CTCs' identification 24 (Figure 3E). These results indicate that sLeX-AP coated CTC- BioT Chip exhibited sufficient capture efficiency to manage CTCs capture and identification from clinical samples which normally had a few to hundreds CTCs mL -1 .…”
Section: Resultsmentioning
confidence: 99%