2021
DOI: 10.1038/s41598-021-99498-0
|View full text |Cite
|
Sign up to set email alerts
|

Biocompatible graphene-zirconia nanocomposite as a cyto-safe immunosensor for the rapid detection of carcinoembryonic antigen

Abstract: Graphene-based materials have gained remarkable attention in numerous disciplines owing to their unique electrochemical properties. Out of various hybridized nanocomposites, graphene-zirconia nanocomposite (GZ) was distinctive due to its biocompatibility. Zirconia nanoparticles serve as spacers that reduce the stacking of graphene and improve the electrochemical performance of the material. Considering that lungs and skin suffer the greatest exposure to nanoparticles, this study aimed to evaluate the cytotoxi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
15
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 13 publications
(15 citation statements)
references
References 73 publications
0
15
0
Order By: Relevance
“…The relative R ct (r R ct )­with the number of electrodes for the magnetic field up (Figure a) and down direction (Figure b) is presented. The sensor response is represented by r R ct , which is the relative R ct difference between SAMs of ds-DNA and the bare Au/Ni thin film . The corresponding mathematical expression used can be expressed as …”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The relative R ct (r R ct )­with the number of electrodes for the magnetic field up (Figure a) and down direction (Figure b) is presented. The sensor response is represented by r R ct , which is the relative R ct difference between SAMs of ds-DNA and the bare Au/Ni thin film . The corresponding mathematical expression used can be expressed as …”
Section: Resultsmentioning
confidence: 99%
“…The sensor response is represented by r R ct , which is the relative R ct difference between SAMs of ds-DNA and the bare Au/Ni thin film. 45 The corresponding mathematical expression used can be expressed as …”
Section: Resultsmentioning
confidence: 99%
“…Apparatus and software.-All data collected were measured using Metrohm Autolab PGSTAT302N 19,20 and data pre-processing was performed using NOVA 1.11 from Metrohm Autolab and Scikit-learn 1.2.2. The machine models were trained using Python 3.10.12, Scikit-learn 1.2.…”
Section: Methodsmentioning
confidence: 99%
“…For a more rapid detection of CEA, Lin and co-workers [41] constructed a special disposable label-free immunosensor which exhibited a limit of detection of 4.25 pg/mL and a limit of quantification of 12.89 pg/mL with a concentration linear range from 0.01 to 10 ng/mL. The fabrication was based on modifying screen-printed carbon electrode (PE) with graphene-zirconia (GZ) nanocomposite functionalized with 1-Pyrenebutyric-Acid-N-hydroxysuccinimide-ester (PYSE) which served as a crosslinker for the immobilization of anti-CEA (Ab).…”
Section: Label-free Ec Immunosensors For Oc Biomarkers Detectionmentioning
confidence: 99%