2016
DOI: 10.1016/j.aca.2016.02.029
|View full text |Cite
|
Sign up to set email alerts
|

Bioanalysis of bevacizumab and infliximab by high-temperature reversed-phase liquid chromatography with fluorescence detection after immunoaffinity magnetic purification

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
24
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
9

Relationship

3
6

Authors

Journals

citations
Cited by 28 publications
(27 citation statements)
references
References 34 publications
0
24
0
Order By: Relevance
“…Some of them are able to measure both IFX and antibodies to IFX, whereas others are specific for one of these quantifications. Most of the available methods rely on an Enzyme‐Linked Immunosorbent Assay (ELISA) technique, whereas alternative ones, based on, for instance, immunoaffinity magnetic purification coupled with high‐temperature reversed‐phase liquid chromatography, fluid‐phase radioimmunoassays (RIA), reporter gene assays and liquid chromatography linked with mass spectrometry are becoming increasingly acknowledged …”
Section: Introductionmentioning
confidence: 99%
“…Some of them are able to measure both IFX and antibodies to IFX, whereas others are specific for one of these quantifications. Most of the available methods rely on an Enzyme‐Linked Immunosorbent Assay (ELISA) technique, whereas alternative ones, based on, for instance, immunoaffinity magnetic purification coupled with high‐temperature reversed‐phase liquid chromatography, fluid‐phase radioimmunoassays (RIA), reporter gene assays and liquid chromatography linked with mass spectrometry are becoming increasingly acknowledged …”
Section: Introductionmentioning
confidence: 99%
“…Our group improved this method and reported the bioanalytical methods for bevacizumab and infliximab. 65 Our methods improved especially the pretreatment process of blood samples compared with the previous report, and by using immunoaffinity magnetic beads, it was possible to achieve both an improvement in accuracy and an increase in sensitivity due to increased recovery rates. The proposed methods could be successfully applied to the clinical samples obtained from patients suffering from cancer and rheumatoid arthritis, after being treated with each drug.…”
Section: Bioanalysis Of Therapeutic Mabs and Adcs As Use Of Intact Prmentioning
confidence: 74%
“…The analysis of macromolecules, such as bDMARDs by HPLC is difficult. Therefore, appropriate pretreatment and suitable conditions of chromatography are necessary to measure bDMARDs in blood . In this study, we developed an assay using HPLC with a fluorescence detection method for TCZ, after it undergoes a simple and rapid pretreatment.…”
Section: Introductionmentioning
confidence: 99%