2006
DOI: 10.1007/s10853-006-0170-0
|View full text |Cite
|
Sign up to set email alerts
|

Bioactive ceramic coatings containing carbon nanotubes on metallic substrates by electrophoretic deposition

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
50
0

Year Published

2008
2008
2014
2014

Publication Types

Select...
3
3
1

Relationship

2
5

Authors

Journals

citations
Cited by 62 publications
(51 citation statements)
references
References 26 publications
1
50
0
Order By: Relevance
“…An efficient mechanical reinforcement of the HA layers can be obtained if the surface of CNTs has been functionalized not only to achieve a good dispersion of CNTs in the ceramic matrix, but also to induce an ideal interface between CNTs and HA. In one of the first published reports on this subject, CNT-reinforced HA layers on Ti -6Al -4V alloy substrates were obtained using sol-gel synthesized nanosized (20 -30 nm) HA particles mixed with multi-walled CNTs (MWCNTs) (Singh et al 2006). Subsequently, homogeneous HA/CNT composite coating layers were obtained using different EPD processing parameters (applied voltage and deposition time) (Kaya 2008;Kaya et al 2008 (Lin et al 2008a).…”
Section: Ha/cnt Compositesmentioning
confidence: 99%
“…An efficient mechanical reinforcement of the HA layers can be obtained if the surface of CNTs has been functionalized not only to achieve a good dispersion of CNTs in the ceramic matrix, but also to induce an ideal interface between CNTs and HA. In one of the first published reports on this subject, CNT-reinforced HA layers on Ti -6Al -4V alloy substrates were obtained using sol-gel synthesized nanosized (20 -30 nm) HA particles mixed with multi-walled CNTs (MWCNTs) (Singh et al 2006). Subsequently, homogeneous HA/CNT composite coating layers were obtained using different EPD processing parameters (applied voltage and deposition time) (Kaya 2008;Kaya et al 2008 (Lin et al 2008a).…”
Section: Ha/cnt Compositesmentioning
confidence: 99%
“…[18] Briefly, Ca(NO 3 ) 2 .4H 2 O and P 2 O 5 were used with a molar ratio of 10:3, to obtain the desired Ca/P ratio necessary for stoichiometric hydroxyapatite which is defined as a synthetic HA with a Ca/P molar ratio that approaches 1.67. 10 ml ethyl alcohol was used as solvent.…”
Section: Synthesis Of Nano-size Hydroxyapatitementioning
confidence: 99%
“…[18] Broad bands located in the range 2500-3500 cm -1 correspond to the moisture in the sample. The phosphate bands were identified at 1090, 1030, 960, 610 and 565 cm -1 and the split bands at 1030 and 1090 cm -1 confirm the formation of a well crystallised apatite structure.…”
Section: Phase Evaluation Of Sol-gel Synthesised Ha Powdersmentioning
confidence: 99%
See 1 more Smart Citation
“…CNTs possess unique mechanical properties. However, there has been only limited work on incorporating CNTs in bioceramic coatings for biomedical applications [9]. The aim of the present work is to utilize cathodic EPD followed by sintering for fabricating bioactive monolithic HA and HA/CNT coatings on Ti6AI4V.…”
Section: Introductionmentioning
confidence: 99%