Our system is currently under heavy load due to increased usage. We're actively working on upgrades to improve performance. Thank you for your patience.
2021
DOI: 10.1016/j.colsurfa.2021.127489
|View full text |Cite
|
Sign up to set email alerts
|

Bio-inspired polydopamine incorporated titania nanotube arrays for biomedical applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 19 publications
(5 citation statements)
references
References 33 publications
0
5
0
Order By: Relevance
“…Nanotubes layered by anodization, in particular, have garnered considerable interest in biomedical implant procedures due to their inherent high quality and costeffectiveness. 1,2 For instance, the titania nanotube arrays (TNA)supports have increased the surface area interaction three times more than common titanium implant surfaces. 3 Several contemporary works have investigated TNA topology, which can solely or communally modulate varied cellular responses to cell adhesion, migration, proliferation, and differentiation.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Nanotubes layered by anodization, in particular, have garnered considerable interest in biomedical implant procedures due to their inherent high quality and costeffectiveness. 1,2 For instance, the titania nanotube arrays (TNA)supports have increased the surface area interaction three times more than common titanium implant surfaces. 3 Several contemporary works have investigated TNA topology, which can solely or communally modulate varied cellular responses to cell adhesion, migration, proliferation, and differentiation.…”
Section: Introductionmentioning
confidence: 99%
“…Nanotubes layered by anodization, in particular, have garnered considerable interest in biomedical implant procedures due to their inherent high quality and cost‐effectiveness 1,2 . For instance, the titania nanotube arrays (TNA)supports have increased the surface area interaction three times more than common titanium implant surfaces 3 .…”
Section: Introductionmentioning
confidence: 99%
“…The sample was employed as a working electrode with a 1 cm 2 exposed surface area. Simulated body fluid (SBF) solution was used for the corrosion investigations [ 15 ]. The sample was submerged for one hour in SBF solution to get a stable open circuit potential (OCP).…”
Section: Methodsmentioning
confidence: 99%
“…The Ti-O-Ti band observed at 565 cm À1 coincides with the phosphate group. 71 The water molecules are observed at 1643 cm À1 . 72 Thus, the functional groups confirmed the formation of apatite in Earle's solution.…”
Section: Immersion Studiesmentioning
confidence: 99%