2020
DOI: 10.1080/10426914.2020.1772483
|View full text |Cite
|
Sign up to set email alerts
|

Bio-ceramic coatings adhesion and roughness of biomaterials through PM-EDM: a comprehensive review

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
27
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 57 publications
(27 citation statements)
references
References 196 publications
0
27
0
Order By: Relevance
“…However, a rapid cooling process results uneven shrinkage of the formed metal alloys, causing residual stress and micro-crack formation. The gases, such as hydrogen, nitrogen, oxygen, and so on, that are produced during the solidification process are released from the machined surface, resulting nanopores and foamy shaped surface [11,34,48,57,[60][61][62].…”
Section: Fundamentals Of Surface Modification Through the Pm-edm Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…However, a rapid cooling process results uneven shrinkage of the formed metal alloys, causing residual stress and micro-crack formation. The gases, such as hydrogen, nitrogen, oxygen, and so on, that are produced during the solidification process are released from the machined surface, resulting nanopores and foamy shaped surface [11,34,48,57,[60][61][62].…”
Section: Fundamentals Of Surface Modification Through the Pm-edm Methodsmentioning
confidence: 99%
“…Since HAp has excellent adaptation to in vivo and in vitro aspects, it possesses superior biocompatibility and osseointegration, which lead to regeneration of the hard tissues. Compared to other bio-ceramics, the abatement potentiality of both the flammable impacts and the adverse chemical reactions in the body by utilizing the HAp-based coating is higher [9,48,[62][63][64][65]. Consequently, a HAp-based coating is proposed as a perfect candidate for enhancing the biocompatibility, mechanical characteristics, and corrosion resistance of biomaterials.…”
Section: Hap and Its Influence On The Response Of Machined Biomaterialsmentioning
confidence: 99%
See 1 more Smart Citation
“…The process is also recommended to fabricate the bio-implants owing to its favorable results in orthopedic fields [ 5 , 6 , 7 ]. The input process parameters namely pulse-on-time, pulse-off-time, current, dielectric medium, spark gap voltage, type of electrode and polarity (negative or positive) play a momentous role in the machining of diverse materials [ 8 , 9 ]. The optimum set of these machining performance parameters has promisingly enhanced the material removal rate and efficiently improves the surface properties [ 10 , 11 ].…”
Section: Introductionmentioning
confidence: 99%
“…This was induced after cessation of a discharge, which leads a surface embedded with added fine particles [ 12 ]. This technique significantly affects the surface characteristics of the modified surface, such as morphological structure and chemical compositional analysis [ 13 ]. Moreover, the surface produced by EDT exhibited superior corrosion-resistance, wear-resistance as compared to the untreated substrate material, and promoted bioactivity [ 14 ].…”
Section: Introductionmentioning
confidence: 99%