2010
DOI: 10.1016/j.jelechem.2010.03.021
|View full text |Cite
|
Sign up to set email alerts
|

Binding of Hg2+ by Cys, Cys-Gly and reduced glutathione: Study by differential pulse voltammetry on rotating Au-disk electrode, electrospray ionization mass-spectrometry and isothermal titration calorimetry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2010
2010
2021
2021

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 22 publications
(8 citation statements)
references
References 30 publications
0
8
0
Order By: Relevance
“…Previous studies have reported the use of ESI with lower-resolution MS to investigate interactions between Hg and simple peptides such as cysteine and glutathione. It was demonstrated that ESI-MS can detect Hg-containing mass signals directly. , Coupled with distinct Hg isotope distribution patterns, characteristic mass peaks of Hg–amino acid or Hg–peptide complexes were identified, mostly under positive ionization mode. , The present study was undertaken to explore the feasibility of using FTICR-MS to directly measure and identify specific Hg–DOM complexes in heterogeneous DOM samples. Stable Hg isotope distribution patterns were used to confirm the Hg–DOM mass peaks and their assigned molecular formulas with a resolution of 400,000 (at m / z 400) and an accuracy of <1 ppm.…”
Section: Introductionmentioning
confidence: 96%
“…Previous studies have reported the use of ESI with lower-resolution MS to investigate interactions between Hg and simple peptides such as cysteine and glutathione. It was demonstrated that ESI-MS can detect Hg-containing mass signals directly. , Coupled with distinct Hg isotope distribution patterns, characteristic mass peaks of Hg–amino acid or Hg–peptide complexes were identified, mostly under positive ionization mode. , The present study was undertaken to explore the feasibility of using FTICR-MS to directly measure and identify specific Hg–DOM complexes in heterogeneous DOM samples. Stable Hg isotope distribution patterns were used to confirm the Hg–DOM mass peaks and their assigned molecular formulas with a resolution of 400,000 (at m / z 400) and an accuracy of <1 ppm.…”
Section: Introductionmentioning
confidence: 96%
“…Protein interactions with small ligands (including co‐factors and drugs) Protein/peptide interactions with metals and ions Protein/peptide interactions with nucleic acids …”
Section: Introductionmentioning
confidence: 99%
“…The flow rate was 1 mL min -1 and the injection volume was 5 µL. working session, and a conditioning potential of -0.6 V was applied during 60 s before each measurement in order to prevent the adsorption of the thiol species on the gold surface [29], avoiding the loss of repeatability caused by the expected decrease of the electroactive surface area of the SPAuE. Chromatographic peak areas were quantified using GPES version 4.9 software in the case of Met, HCys, Cys and GSH whereas NAC area was quantified by chemometric deconvolution using a home-made Matlab program based on the fitting of overlapping signals to the exponentially modified gaussian (EMG) function [33].…”
Section: Chromatographic Systemmentioning
confidence: 99%
“…On the one hand, it has been reported that noble metals, like gold and silver, can be very convenient for the determination of aminothiols due to their affinity for thiol groups [27,[29][30][31]. On the other hand, the use of screen-printed electrodes (SPE) has been postulated as a very convenient alternative to conventional solid electrodes due to their intrinsic characteristics, such as low-cost character and three-electrode configuration printed on the same strip [32].…”
Section: Introductionmentioning
confidence: 99%