2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society 2012
DOI: 10.1109/embc.2012.6345889
|View full text |Cite
|
Sign up to set email alerts
|

Binary signals in impedance spectroscopy

Abstract: Using of binary waveforms in the fast impedance spectroscopy of biological objects is discussed in the paper. There is shown that the energy of binary waveforms can be concentrated onto selected separate frequencies. We can optimize the binary excitation waveform depending on the shape of frequency response of the impedance under study to maximize the levels of signal components with certain selected frequencies. As a result, we are able to receive maximal amount of information about the properties and behavio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(8 citation statements)
references
References 11 publications
0
8
0
Order By: Relevance
“…While in this study only rectangular waveforms with a fixed frequency (1 kHz) and duty cycle (50%) have been used, it is possible to synthesize and apply pulse-width-modulated binary signals with tailored frequency spectra [9]. The voltage excitation would then be switched (e.g.…”
Section: Discussionmentioning
confidence: 99%
“…While in this study only rectangular waveforms with a fixed frequency (1 kHz) and duty cycle (50%) have been used, it is possible to synthesize and apply pulse-width-modulated binary signals with tailored frequency spectra [9]. The voltage excitation would then be switched (e.g.…”
Section: Discussionmentioning
confidence: 99%
“…More often only measuring several to tens of distinct frequencies (usually with large frequency intervals) is satisfactory. Therefore, the spectral sparse signals whose energy concentrates on the expected limited spectral lines, such as the sparse spectrum sequence (SSS) [ 27 ], the authors' MFM signals [ 22 ], and the MFS signals proposed in this paper, are more reasonable. According to the literature [ 27 ], a sample of the SSS signal has 76.2% of the total signal energy distributed equally on its four harmonics (1, 3, 5, 7).…”
Section: Discussionmentioning
confidence: 99%
“…For example, in Z ex1 , the peaks only reached a constant value on days 1, 8 and 12. Nevertheless, in Z ex4 , the peak value stabilized on days 1,6,8,10,11,12,15,16. Therefore, we can suppose that, when the curve reaches a constant value, this means that the muscle is exhausted.…”
Section: Initial Position Arms Straightmentioning
confidence: 94%
“…However, the time necessary to secure a full spectrum might be too large for some applications [11]. In living beings, there are processes that occur quickly and the traditional EBIS could not monitor them [12]. The fast EBIS also avoids artifacts caused by an MUT involuntary movement, which may lead to changes in the contact interface (electrode-electrolyte) and cause errors during the measurement [13].…”
Section: Introductionmentioning
confidence: 99%