1996
DOI: 10.1016/s0363-5023(96)80309-1
|View full text |Cite
|
Sign up to set email alerts
|

Biaxial total-wrist arthroplasty

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
59
0
11

Year Published

2005
2005
2021
2021

Publication Types

Select...
6
3
1

Relationship

0
10

Authors

Journals

citations
Cited by 143 publications
(73 citation statements)
references
References 12 publications
3
59
0
11
Order By: Relevance
“…Biaxal (Depuy, Warsaw, Ind.,) [12,13], Meuli (Sulzer Orthopaedics Ltd., Winterthur, Switzerland) [14][15][16], Volz (Howmedica Company, Rutherford, NJ, USA) [17][18][19], en Trispherical (Osteonics, Allendale, NJ, USA) [20,21] are the most commonly used devices in North America. Problems with this prosthesis are implanting loosening, periprosthetic bone resorption and wrist imbalance.…”
Section: Discussionmentioning
confidence: 99%
“…Biaxal (Depuy, Warsaw, Ind.,) [12,13], Meuli (Sulzer Orthopaedics Ltd., Winterthur, Switzerland) [14][15][16], Volz (Howmedica Company, Rutherford, NJ, USA) [17][18][19], en Trispherical (Osteonics, Allendale, NJ, USA) [20,21] are the most commonly used devices in North America. Problems with this prosthesis are implanting loosening, periprosthetic bone resorption and wrist imbalance.…”
Section: Discussionmentioning
confidence: 99%
“…discussion TWA achieves satisfactory early outcome in terms of pain relief and motion, [13][14][15] but in the long term it shows a high rate of implant failure 16 and silicone Table 2 Pre-and post-operative range of motion, Disabilities of the Arm, Shoulder and Hand (DASH) score, and patient-rated wrist evaluation (PRWE) score synovitis. 13 There are different TWA designs (Meuli, Volz, biaxial, trispherical, and the GUEPAR) [2][3][4][5][6][7] ; each has varying degrees of success and complications (implant loosening, peri-prosthetic bone resorption, and wrist imbalance). For the Menon or Universal prosthesis, the concave articular surface of the radial component has 20º of radial inclination and a Y-shaped tie mesh stem for fixation.…”
Section: Vol 20 No 3 December 2012mentioning
confidence: 99%
“…However, in the wrist joint, prostheses lacks longevity and histocompatibility. [3][4][5] Total wrist arthroplasty has also been found to be unsuitable for severe joint malformation, chronic subluxion, and collapse of the carpal bone. 6 It is clear that optimum treatments are required for each stage of RA joint destruction.…”
Section: Introductionmentioning
confidence: 99%