Biaxial-EDC Test Attempts With Pre-Cracked Zircaloy-4 Cladding Tubes

Abstract: When the pellet-cladding mechanical interaction (PCMI) occurs in a reactivity-initiated accident (RIA), the states of stress and strain in the fuel cladding varies in a range depending on the friction and degree of bonding between cladding and pellet. Japan Atomic Energy Agency has developed the improved Expansion-due-to-compression (EDC) test apparatus to investigate the PCMI failure criterion of high-burnup fuel under such conditions. In this study, the failure behavior of cladding tube was investigated by u… Show more