Optical Fiber Communication Conference/National Fiber Optic Engineers Conference 2011 2011
DOI: 10.1364/nfoec.2011.pdpd6
|View full text |Cite
|
Sign up to set email alerts
|

Bi-Directionally Amplified Extended Reach 40Gb/s CWDM-TDM PON with Burst-Mode Upstream Transmission

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
2
0

Year Published

2012
2012
2019
2019

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 16 publications
(4 citation statements)
references
References 1 publication
0
2
0
Order By: Relevance
“…The state-of-the art in this field is a hybrid 4 stacked PON (4x10G downstream and 4x10G upstream) [11]. DISCUS is evaluating a single carrier 40Gb/s downstream solution based on electrical duo-binary modulation of a high-power, external cavity laser, monolithically integrated with an electro-absorption modulator and booster semiconductor optical amplifier.…”
Section: Technology Evolutionmentioning
confidence: 99%
“…The state-of-the art in this field is a hybrid 4 stacked PON (4x10G downstream and 4x10G upstream) [11]. DISCUS is evaluating a single carrier 40Gb/s downstream solution based on electrical duo-binary modulation of a high-power, external cavity laser, monolithically integrated with an electro-absorption modulator and booster semiconductor optical amplifier.…”
Section: Technology Evolutionmentioning
confidence: 99%
“…Most of these have limited the optical distribution network (ODN) to exclusively use power splitters to offer maximum operational flexibility as it allows all users to access all wavelengths [7]- [9]. However, wavelength splitting allows larger total splitting ratios for a given link budget so the combination of wavelength and power splitting allows a larger total splitting ratio than power splitting alone [11]- [14]. These contributions focus on operational benefits of centralizing the switching equipment and assume the existence of a powered remote CO.…”
Section: Introductionmentioning
confidence: 99%
“…Both long distance transmission and high splitting ratio result in high link loss therefore the loss budget is a key parameter for a long-reach PON. Even though electrical or optical repeaters in the remote node can improve the transmission distance and loss budget [8]- [10], truly passive reach is preferred in order to keep the "passive" characteristic of PON system. External modulation combined with coherent detection has been considered as a good solution for long reach and high loss budget [9], [10].…”
Section: Introductionmentioning
confidence: 99%
“…Even though electrical or optical repeaters in the remote node can improve the transmission distance and loss budget [8]- [10], truly passive reach is preferred in order to keep the "passive" characteristic of PON system. External modulation combined with coherent detection has been considered as a good solution for long reach and high loss budget [9], [10]. Using complex modulation format and coherent digital receiver in optical line terminal (OLT) and/or optical network unit (ONU), symmetric 10G-PON with loss budget up to 53 dB [11] and 51 dB [12] (considering the FEC limit BER of 3.8 × 10 −3 ) have been achieved.…”
Section: Introductionmentioning
confidence: 99%