2018
DOI: 10.1021/acs.analchem.8b01632
|View full text |Cite
|
Sign up to set email alerts
|

Beyond Fourier Transform Infrared Spectroscopy: External Cavity Quantum Cascade Laser-Based Mid-infrared Transmission Spectroscopy of Proteins in the Amide I and Amide II Region

Abstract: In this work, we present a setup for mid-IR measurements of the protein amide I and amide II bands in aqueous solution. Employing a latest generation external cavity-quantum cascade laser (EC-QCL) at room temperature in pulsed operation mode allowed implementing a high optical path length of 31 μm that ensures robust sample handling. By application of a data processing routine, which removes occasionally deviating EC-QCL scans, the noise level could be lowered by a factor of 4. The thereby accomplished signal-… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

2
66
0
1

Year Published

2018
2018
2024
2024

Publication Types

Select...
5
3

Relationship

1
7

Authors

Journals

citations
Cited by 86 publications
(69 citation statements)
references
References 46 publications
2
66
0
1
Order By: Relevance
“…Infrared (IR) spectra were recorded by an external-cavity quantum cascade laser-based IR transmission setup described in detail by Schwaighofer et al [ 31 ]. A water-cooled external-cavity quantum cascade laser (Hedgehog, Daylight Solutions Inc., San Diego, USA) was used operating at a repetition rate of 100 kHz and a pulse width of 5000 ns.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Infrared (IR) spectra were recorded by an external-cavity quantum cascade laser-based IR transmission setup described in detail by Schwaighofer et al [ 31 ]. A water-cooled external-cavity quantum cascade laser (Hedgehog, Daylight Solutions Inc., San Diego, USA) was used operating at a repetition rate of 100 kHz and a pulse width of 5000 ns.…”
Section: Methodsmentioning
confidence: 99%
“…Quality attributes (or key performance indicator) of IBs, such as titer and morphology changes during extraction procedures have already been studied and show that IBs are dynamic structures depending on the cultivation and extraction conditions [ 27 29 ]. First approaches towards IB sizing in the upstream process have already been made within our group by Reichelt et al [ 30 ] using transmission electron microscopy [ 31 ] in combination with nanoparticle tracking analysis (NTA) revealing general trends of IB growth during cultivation. Further studies show that IBs consist of up to 50% correctly folded protein in contrast to the general perception of IBs as inactive structures [ 29 , 32 ].…”
Section: Introductionmentioning
confidence: 99%
“…Standard Fourier transform infrared spectroscopy (FTIR) is considered as a benchmark due to its broadband spectral coverage spanning over the entire mid-infrared spectral region and highly accurate wavelength scale. In addition, the spectra can be averaged for a long time to reach high detection sensitivities [ 18 ]. However, FTIR systems are bulky, expensive, have a short interaction path length and require a long acquisition/averaging time to achieve high sensitivity.…”
Section: Introductionmentioning
confidence: 99%
“…Specifically, rotation of the grating in the external cavity introduces mode-hops due to the change of the laser cavity length and results in a spectral mismatch in the recordings of consecutive scans. Consequently, in the broadband tuning of the EC-QCL, low noise levels are hard to achieve due to the difficulty of averaging the consecutive scans efficiently [ 18 ]. This effect is reduced significantly in the narrowband scan which is performed by tuning the piezo actuator(s) mounted on the diffraction grating.…”
Section: Introductionmentioning
confidence: 99%
“…As this is an online coupled technique, the time for the IR measurements is also limited (e.g., 15 s) to retain the resolution in the SEC size separation. Comparable method development work was done by Lendl and co‐workers where they coupled liquid adsoption chromatography, LAC, to a QCL setup to measure sugars in beverages and later stand‐alone QCL setups were used to measure biological applications such as proteins in aqueous solutions, glucose levels, and multianalyte blood analysis . Analog correlation between chemical composition and molecular weight are currently conducted via SEC‐NMR indicating the needs for the acquisition of correlated information .…”
mentioning