2014
DOI: 10.1126/science.1256358
|View full text |Cite
|
Sign up to set email alerts
|

Beyond blob-ology

Abstract: Advanced cryo–electron microscopy yields high-resolution structures of proteins

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
24
0
1

Year Published

2015
2015
2020
2020

Publication Types

Select...
8
1
1

Relationship

1
9

Authors

Journals

citations
Cited by 47 publications
(25 citation statements)
references
References 14 publications
0
24
0
1
Order By: Relevance
“…Recent advances in single particle cryo-EM instrumentation and data processing have facilitated the calculation of high-resolution 3D-maps of biomolecules as small as 60 kDa (Bai et al, 2015; Smith and Rubinstein, 2014; Khoshouei et al, 2016). Figure 7A–B show cryo-EM density maps of free and RNF169-bound NCPs, determined at 8.1 and 6.6 Å resolution, respectively (Figure 7—figure supplement 1).…”
Section: Resultsmentioning
confidence: 99%
“…Recent advances in single particle cryo-EM instrumentation and data processing have facilitated the calculation of high-resolution 3D-maps of biomolecules as small as 60 kDa (Bai et al, 2015; Smith and Rubinstein, 2014; Khoshouei et al, 2016). Figure 7A–B show cryo-EM density maps of free and RNF169-bound NCPs, determined at 8.1 and 6.6 Å resolution, respectively (Figure 7—figure supplement 1).…”
Section: Resultsmentioning
confidence: 99%
“…Although several models that have attempted to model the G. sulfurreducens pilus structure have questioned whether sufficient pi‐pi stacking of aromatic amino acids for metallic‐like conductivity is possible (Feliciano et al ., ; Boesen and Nielsen, ; Bonanni et al ., ; Reardon and Mueller, ), actual experimental results trump modelling, which can be based on faulty assumptions, and the recent EFM imaging of charge propagation (Malvankar et al ., ) further supports the abundant experimental evidence (Malvankar et al ., ; Vargas et al ., ) supporting metallic‐like conductivity. At this point, structural studies, potentially taking advantage of recent advances in cryo‐electron microscopy (Glaeser, ; Smith and Rubinstein, ), are more likely to advance understanding of the features that confer metallic‐like conductivity than will theoretical modelling.…”
Section: Discussionmentioning
confidence: 99%
“…Anisotropic magnification in electron microscope images of 2D crystals was first described more than 30 years ago [1] but more recently has not been detected with most modern electron microscopes used under conditions typical for cryo-EM with film or charge-coupled device (CCD) cameras. Direct detector device (DDDs) cameras have revolutionized single particle electron cryomicroscopy (cryo-EM) [2,3]. Two DDD manufacturers, Gatan and Direct Electron, have produced cameras with pixel sizes between 5.0 and 6.5 µm, which is significantly smaller than is typical with CCD cameras.…”
Section: Introductionmentioning
confidence: 99%