1984
DOI: 10.1007/bf01458961
|View full text |Cite
|
Sign up to set email alerts
|

Bestimmung der Molmassenverteilung sowie der Stabilit�tsgrenze von Polyacrylamiden unter Benutzung einer kombinierten Ausschlu�chromatographie/Kleinwinkel-Laser-Streulichtphotometer Anlage

Abstract: Verzeichnis derThe molecular weight distribution including the calculation of M n, M~ and M z of polyacrylamide in aqueous 0.1 M sodium sulphate-solution has been determined by simultaneously and continuously monitoring the effluent from a size-exclusion chromatographic (SEC) column filled with porous glasses with a low-angle-laser-light-scattering (LALLS) photometer. The recorder traces of the scattering intensity and the refractive index difference have been digitalized in about 400 steps corresponding to 20… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
5
0
1

Year Published

1986
1986
2010
2010

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 25 publications
(7 citation statements)
references
References 35 publications
1
5
0
1
Order By: Relevance
“…This might be an indication that some association or aggregation effects were still present within the sample solution. Those structures could then be degraded by the shear force induced at higher concentrations (Kulicke and Bo¨se 1984). However, this should as well led to significant changes of the ratio between light scattering and refractive index signal intensities (Figure 2a, b).…”
Section: Resultsmentioning
confidence: 90%
“…This might be an indication that some association or aggregation effects were still present within the sample solution. Those structures could then be degraded by the shear force induced at higher concentrations (Kulicke and Bo¨se 1984). However, this should as well led to significant changes of the ratio between light scattering and refractive index signal intensities (Figure 2a, b).…”
Section: Resultsmentioning
confidence: 90%
“…Light-scattering measurements were performed using a coupled system of various apparatuses consisting of an SEC unit, a multiangle laser light scattering photometer (Dawn DSP; Wyatt Technology Corp., Santa Barbara, CA; ϭ 633 nm), and a concentration detector (Shodex RI-71; Showa Denko, Tokyo, Japan) at 25°C (15,16,18,20). Chitosan samples were dissolved in an eluent (0.1 vol% CF 3 COOH, 0.1 mol/liter NaCl) by shaking (12 h) and polymer solutions (1 mg/ml) were filtered using a 0.45-m membrane filter.…”
Section: Methodsmentioning
confidence: 99%
“…Dariiber hinaus treten in Schuttungen von porosen Kugeln, wie sie bei der AusschluR-Chromatographie fur die Bestimmung der Molmassen-Verteilung von Polymeren verwendet werden, starke Dehnstromungen auf. In solchen Dehnstromungen konnen bei den ublicherweise verwendeten DurchfluRraten von 1 ml/min Degradationen der Polymer-Molekule schon bei relativ kleinen Molmassen beobachtet werden, was bislang nicht bekannt war [3]. Es ist daher das Ziel der vorliegenden Arbeit, qualitativ und quantitativ zu untersuchen, unter welchen Bedingungen beim Stromen von Polymer-Losungen in porosen Medien Degradationserscheinungen auftreten.…”
Section: Degradation Von Polymer-molekulen Beim Durchstromen Poroser unclassified