BESSRC-CAT bending magnet beamline at the advanced photon source

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
37
0

Year Published

2003
2003
2020
2020

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 48 publications
(38 citation statements)
references
References 3 publications
1
37
0
Order By: Relevance
“…61,62 Plutonium L 3 -edge X-ray absorption data were acquired in the conventional 45/45°configuration with a 13-element fluorescence detector (without slits and filters) on bending magnet station 12-BM-B with a Rh focusing mirror and Si⟨111⟩ monochromator. 63 The incident X-ray energy was calibrated using Zr foil by setting the inflection point in the first differential XANES to 17.998 eV. The data in the XANES region were acquired at 0.8 eV/pt, between 18.027 and 18.102 keV, for the purpose of linear regression analysis and XANESfitting.…”
Section: ■ Experimental Methodsmentioning
confidence: 99%
“…61,62 Plutonium L 3 -edge X-ray absorption data were acquired in the conventional 45/45°configuration with a 13-element fluorescence detector (without slits and filters) on bending magnet station 12-BM-B with a Rh focusing mirror and Si⟨111⟩ monochromator. 63 The incident X-ray energy was calibrated using Zr foil by setting the inflection point in the first differential XANES to 17.998 eV. The data in the XANES region were acquired at 0.8 eV/pt, between 18.027 and 18.102 keV, for the purpose of linear regression analysis and XANESfitting.…”
Section: ■ Experimental Methodsmentioning
confidence: 99%
“…To characterize the clean sample surface, high resolution specular X-ray reflectivity data were collected at beamline 12-BM (BESSRC/XOR) at the Advanced Photon Source (APS), Argonne National Laboratory (ANL) (Beno et al, 2001a). The hematite sample was mounted in deionized water in a thin film cell sealed with 8 lm Kapton ä film on a four-circle diffractometer.…”
Section: X-ray Reflectivity Measurements and Analysismentioning
confidence: 99%
“…48 The energy bandwidth afforded by the beamline configuration was estimated to be 1 eV at the L 3 -edge energy, providing an instrumental resolution that is more than 4× smaller than the natural line width of 4.35 eV for the Er L 3 core hole. 49 Hence, the Er L 3 -edge XANES (X-ray absorption near edge structure) obtained here are negligibly broadened (≤3%) by the instrumental resolution function.…”
Section: ■ Experimental Methodsmentioning
confidence: 96%