Benzo‐18‐crown‐6 and its lariat ether derivatives as ionophores for potassium, strontium, and lead ion‐selective electrodes

Abstract: Ion-selective microelectrodes were prepared by coating a matrix containing the crown ether benzo-18-crown-6 or one of five polyether ring-substituted benzo-18-crown-6 derivatives on a preconditioned silver wire in a flow cell. Responses of the electrodes toward lithium, sodium, potassium, magnesium, calciuni, strontium, and lead were measured. Selectivity coefficients were obtained by the matched potential, fixed interference, and separate solution methods. Compared with benzo-18-crown-6, the nature of the sid… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
26
1

Year Published

1998
1998
2010
2010

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 29 publications
(27 citation statements)
references
References 17 publications
(7 reference statements)
0
26
1
Order By: Relevance
“…Numerous types of ion selective electrodes (ISEs) for alkali and alkaline earth metal ions based on crown ethers 1,2 have been prepared and studied. A large number of ISEs have been developed because of applications in clinical and industrial measurements.…”
Section: Introductionmentioning
confidence: 99%
“…Numerous types of ion selective electrodes (ISEs) for alkali and alkaline earth metal ions based on crown ethers 1,2 have been prepared and studied. A large number of ISEs have been developed because of applications in clinical and industrial measurements.…”
Section: Introductionmentioning
confidence: 99%
“…There are many reports of the use of plasticized PVC membrane as potassium ion selective electrode (ISE). [10][11][12][13][14][15][16][17][18][19][20][21][22][23][24] The plasticized PVC membrane was prepared from a typical mixture of neutral-carrier-type ionophore, ion-exchanging material, and plasticizer. During development of the CCD potassium ion sensor, however, poor adhesion of plasticized PVC membranes to the device surface was an obstacle.…”
Section: Introductionmentioning
confidence: 99%
“…Past attempts [2][3][4][5][6][7][8][9] to develop a selective membrane electrode for strontium have not been very successful. Most of these exhibited high response time, limited pH range or significant interference from other alkaline earth metals.…”
Section: Introductionmentioning
confidence: 99%
“…Most of these exhibited high response time, limited pH range or significant interference from other alkaline earth metals. These electrodes are based on neutral carrier [2][3][4][5][6] and ion exchangers. [7][8][9] Thus, there is a need to explore other materials like calixarenes, tweezers and dendrimers which may show high selectivity towards Sr 2+ .…”
Section: Introductionmentioning
confidence: 99%