Volume 12 Number 2 2016
DOI: 10.18057/ijasc.2016.12.2.5
|View full text |Cite
|
Sign up to set email alerts
|

Behaviour of Semi-Rigid Steel Frames With Steel Plate Shear Walls

Abstract: This paper describes an investigation on the seismic behaviour of a new lateral resistance system which combines semi-rigid steel frames (SRSFs) with steel plate shear walls (SPSWs). A laboratory test, including two 1/3-scale one-bay, two-storey SRSFs with SPSWs, was conducted to study the influence of the stiffeners on SPSWs and the stiffness of beam-column connections. The results indicate that the new system inherits the merits both of SRSFs and SPSWs. It exhibits excellent seismic performance in terms of l… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
7
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(7 citation statements)
references
References 12 publications
(12 reference statements)
0
7
0
Order By: Relevance
“…Consequently, the beam-column connection joints rotate evidently, the rotational stiffness of connection joints degrades steadily and finally the end plates of the intermediate beam enter the plastic stage. Besides, the form of beam-column connection also affect the performance of the SPSW structure, and the yielding load of the SPSW with rigid beam-column connections is 16.3% higher than that with hinged beam-column connections (Yu and Hao 2016), which shows that the rotation and stiffness degradation of the beam-column connection reduce of the structural bearing capacity. However, due to the presence of precast RC cover panels in the Con-BRP, the rotation and stiffness degradation of flush end-plate beam-column connection joints are not significant.…”
Section: Rotation Of Beam-column Connection Jointsmentioning
confidence: 99%
See 2 more Smart Citations
“…Consequently, the beam-column connection joints rotate evidently, the rotational stiffness of connection joints degrades steadily and finally the end plates of the intermediate beam enter the plastic stage. Besides, the form of beam-column connection also affect the performance of the SPSW structure, and the yielding load of the SPSW with rigid beam-column connections is 16.3% higher than that with hinged beam-column connections (Yu and Hao 2016), which shows that the rotation and stiffness degradation of the beam-column connection reduce of the structural bearing capacity. However, due to the presence of precast RC cover panels in the Con-BRP, the rotation and stiffness degradation of flush end-plate beam-column connection joints are not significant.…”
Section: Rotation Of Beam-column Connection Jointsmentioning
confidence: 99%
“…For unstiffened and stiffened SPSWs, numerous studies have been carried out considering the influence of beam-column connection characteristics (Yu and Hao 2016;Guo et al 2017). Based on the widely adopted principle of large ductility without brittle fracture, the flush end-plate connection holding of the merit of simple construction has been employed in many researches on SPSW with semirigid connected frame.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The availability of a large database on the actual M-θ characteristics of various connections makes it possible to conduct extensive verification of the rigidity and classification indices proposed by AISC and Eurocode 3 "EC3". To this end, over the past few decades, a great deal of effort has been expended within the research arm of the structural engineering profession to address the topic of classification of connections and their impact on the structural response [3][4][5][6][7][8][9][10]. These analyses mainly involve the calculation of stiffness and strength from the experimental M-θ curve, which is validated using Finite Element analyses.…”
Section: Introductionmentioning
confidence: 99%
“…Most of experimental studies mentioned above have been focused on performance of SPSW test specimens with the moment resisting (rigid) connections between the boundary elements. There are also some studies examined seismic behaviors of steel frames with semi-rigid beam-column connections [24][25][26][27]. In SPSW systems, boundary elements with rigid beam-column connections require the use of larger structural sections to be capable of resisting the induced flexural demand.…”
Section: Introductionmentioning
confidence: 99%