Beam tests of the balloon-borne ATIC experiment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
9
0

Year Published

2008
2008
2018
2018

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 20 publications
(9 citation statements)
references
References 11 publications
(10 reference statements)
0
9
0
Order By: Relevance
“…Only one such measurement has thus far been realized in space flight, the Cosmic-Ray Nuclei detector (CRN) that was flown on the Space Shuttle (L'Heureux et al 1990). Long-duration balloon (LDB) flights permit exposures of the order of weeks, and several LDB instruments have been developed: TRACER (Transition Radiation Array for Cosmic Energetic Radiation) (Ave et al 2011), which is the subject of this paper, and two instruments that use short calorimeters for the energy measurement, ATIC (Ganel et al 2005) and CREAM (Ahn et al 2007). TRACER was designed and constructed at the University of Chicago, utilizing the heritage of CRN.…”
Section: Introductionmentioning
confidence: 99%
“…Only one such measurement has thus far been realized in space flight, the Cosmic-Ray Nuclei detector (CRN) that was flown on the Space Shuttle (L'Heureux et al 1990). Long-duration balloon (LDB) flights permit exposures of the order of weeks, and several LDB instruments have been developed: TRACER (Transition Radiation Array for Cosmic Energetic Radiation) (Ave et al 2011), which is the subject of this paper, and two instruments that use short calorimeters for the energy measurement, ATIC (Ganel et al 2005) and CREAM (Ahn et al 2007). TRACER was designed and constructed at the University of Chicago, utilizing the heritage of CRN.…”
Section: Introductionmentioning
confidence: 99%
“…The calorimeter is comprised of 8 layers of 40 BGO crystals in each layer in ATIC-2 and of 10 layers in ATIC-4. The details of construction of the apparatus and the procedures of its calibration are given in Guzik et al (2004); Zatsepin et al (2004); Ganel et al (2005); Panov et al (2008).…”
Section: Introductionmentioning
confidence: 99%
“…As a result, the energy resolution for electrons of the instrument was high in the total energy range of 30 GeV-1 TeV. The simulation predicted and the beam tests confirmed that the resolution, in terms of half width on the half height, was not worse than 3% [106] (see Figure 20). Such high resolution, together with relatively high statistics, allows a meaningful measurement of the electron spectrum in the high-resolution mode -with energy bins as small as 5-8% (0.020-0.035 of decimal logarithm of energy).…”
Section: The Fine Structure Of the Electron Spectrum Measured By The mentioning
confidence: 59%
“…In the range of 200-810GeV, there were 701 events studied for statistical significance of the structure. and the procedures of its calibration are given in [107,108,106,109]. The calorimeter of ATIC was thick for electrons.…”
Section: The Fine Structure Of the Electron Spectrum Measured By The mentioning
confidence: 99%
See 1 more Smart Citation